Finden Sie schnell tioilette für Ihr Unternehmen: 508 Ergebnisse

RE-2G(St)HSWAH-CI-TIMF FE180

RE-2G(St)HSWAH-CI-TIMF FE180

HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7MULTI-TRIPLE, SILICONE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Core identification: Black / Blue / Red; with numbered tape under, separator tape of the pair screen, Upon request ; Black / Blue / Red cores numbered 1-1-1, 2-2-2,…, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 300 MΩ.km Mutual Capacitance: max. 150 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω
Rohrteile aus Stahl, Rohrdoppelnippel Nr. 23, 2x AG, Gröditzer Fittings, 3/4" - 140 mm

Rohrteile aus Stahl, Rohrdoppelnippel Nr. 23, 2x AG, Gröditzer Fittings, 3/4" - 140 mm

Rohrdoppelnippel Nr.23 Die Norm DIN EN 10241 ist die Basis für die Angebote an Stahlfittings und Rohrteilen. Es sind Gewindefittings aus geschweißten oder nahtlosen Rohren, Schmiedestücken und gewalzten Stäben. Sie sind für Transport von Flüssigkeiten und Gas zugelassen. Galvanische Verzinkung auf Anfrage – blauchromat – schwarzchromat 04_Artikelnummer: 222050140 02_Dimension: 3/4" - 140 mm 05_Gewinde: Außengewinde: R (konisch) 01_Katalognummer: 23 08_DIN-Norm: DIN EN 10241 10_Gewicht in Gramm: 235
SMD 5050-Chip-Modul, 120°

SMD 5050-Chip-Modul, 120°

LED-Leuchtmittel, 4x1 LED, SMD 5050-Chip-Modul, 120°, Kabelanschluss, DC 12 V, ca. 1 W, ca. 100 Lm, kaltweiß 5700 K, IP65, A+, z.B. für Leuchtkästen / Werbeschilder Artikelnummer: LED4x1M12LKW EAN: 4260373594162
RE-2Y(St)H & RE-2X(St)H

RE-2Y(St)H & RE-2X(St)H

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & MULTI-TRIPLE, XLPE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
Patchkabel RJ45 6kV Flex500 Outdoor AWG 24

Patchkabel RJ45 6kV Flex500 Outdoor AWG 24

‧ RJ45 Patchkabel für Industrie und Außenanwendungen ‧ geschirmtes Cat.5e, Class EA RJ45 Patchkabel ‧ Einhaltung des Klasse EA Channel-Link nach ISO/IEC 11801-1, DIN EN 50173-1 ‧ getestet: Channel-Link bis 500 MHz ‧ für 10 GBit/s Ethernet (IEEE 802.3an) bis 40m geeignet ‧ besonders geeignet für ungeschirmte und geschirmte Class EA Systeme ‧ Robustes und abriebfestes Kabel für die Industrieanwendung, wie im Maschinen- und Anlagenbau. Ebenfalls geeignet für die Verlegung im Freien ‧ Einhaltung der VDE-AR-N 4100:2019-04 (6KV Stoßspannungsprüfung nach DIN EN 60664-1) bei Verlegung in Zählerplatz und Elektroverteilern ‧ Kabeltyp: S/UTP 4x2xAWG24/7 ‧ Kabelmantel LSHF (FRNC) PUR; schwarz ‧ Das Kabel ist für wiederholte bewegte Anwendung (Schleppkette) konstruiert. Getestet mit einem Biegeradius von 100mm und einer Beschleunigung von 4m/s² wurden 3 Mio. Zyklen bei Raumtemperatur erreicht. ‧ zwei geschirmte RJ45-Stecker, Beschaltung 1 - 1 ‧ UV; Öl beständig ‧ Remote Powering (PoE, PoE plus und UPoE) für IoT; M2M, IoT; HDBaseT; Industrie 4.0; Multimedia; Breitband-Video geeignet ‧ Knickschutztülle umspritzt ‧ deutlich längere Haltbarkeit als Standard-Patchkabel ‧ sehr kurze Knickschutztülle
RE-2YCY-fl-PIMF

RE-2YCY-fl-PIMF

INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: Braid of tinned Cu wires, 85% coverage Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2Y(St)YSWAY-fl & RE-2X(St)YSWAY-fl MP

RE-2Y(St)YSWAY-fl & RE-2X(St)YSWAY-fl MP

INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)YSWAY-fl,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTİVE SCREENED, ARMOURED, PVC SHEATHEDRE-2X(St)YSWAY-fl,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Inner sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Outer sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
LED-UV Kettenförderer

LED-UV Kettenförderer

Anders als Quecksilberdampflampen nutzt die LED-Härtung halbleiterbasierende LEDs zur Erzeugung ultravioletten (UV) Lichts.
RJ45 Cat.6 Ultraflex500 VoIP Patchkabel AWG 26

RJ45 Cat.6 Ultraflex500 VoIP Patchkabel AWG 26

‧ optimale Lösung bei Platzmangel ‧ besonders geeignet für ungeschirmte und geschirmte Class EA Systeme ‧ vollgeschirmtes Cat.6 Patchkabel AWG 26/7 ‧ zwei geschirmte RJ45-Stecker, Beschaltung 1 - 1 ‧ Kabeltyp: S/FTP 4x2xAWG 26/7 PIMF ‧ Kabelmantel PUR ‧ sehr kurze Knickschutztülle ‧ besonders geeignet für VoIP Endgeräte ‧ Biegeradius von bis zu 10 mm möglich ‧ deutlich längere Haltbarkeit als Standard-Patchkabel ‧ problemlos bis zu 8500 Bewegungszyklen unter Belastung
RE-2Y(St)2YSWAY-fl-TIMF

RE-2Y(St)2YSWAY-fl-TIMF

INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , ,0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type 03 Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,… Triple: Two conductors twisted to a pair TIMF Construction: Polyester tape above the triple, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PE compound, BS 6234 Type 03, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
RE-2Y(St)Y-fl

RE-2Y(St)Y-fl

INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1SİNGLE & MULTİ-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , ,0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type03 Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…) Triple: Two conductors twisted to a pair Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
HEJU Bendy Micro-S Ladekabel

HEJU Bendy Micro-S Ladekabel

Ultraflexibel laden: das neue Micro-USB-Kabel in der Kurz-Version. Artikelnummer: 950530-2 Druckbereich: 10 x 10 mm Gewicht: 9 g Maße: 125 x 11 x 8 mm Verpackung: Kartonbox mit Fenster
RE-2Y(St)H & RE-2X(St)H

RE-2Y(St)H & RE-2X(St)H

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1RE-2Y(St)H,SİNGLE & MULTİ-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHEDRE-2X(St)H,SİNGLE & MULTİ-TRIPLE, XLPE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Note: Other core configurations manufactured upon request Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Triple: Three conductors twisted to a triple Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
HEJU Twirl Ladekabel

HEJU Twirl Ladekabel

Zwei Anschlüsse „im Handumdrehen“: Micro-USB-Stecker auf der einen, Lightning-Anschluss auf der anderen Seite. Mit praktischer Magnet-Funktion, zum Beispiel zum Befestigen am Schlüsselring. Artikelnummer: 1091023-5 Druckbereich: 18 x 5 mm Gewicht: 9 g Größe: 120 x 63 x 12 mm Maße: 110 x 13 x 10 mm Verpackung: Polybeutel
STAIGER – Systemlösungen & Baugruppen

STAIGER – Systemlösungen & Baugruppen

Crimpen, löten, laminieren, umspritzen und Leiterplatten bestücken: Das tun viele – aber nur wenige vereinen all diese Techniken unter einem Dach. STAIGER bietet Ihnen diese wichtige Kombination. STAIGER – Lösungen mit System Dank unserer Kompetenz in Verbindungs-, Bestückungs- und Umspritztechniktechnik sind wir der ideale Fertigungspartner für anspruchsvolle, einbaufertige Baugruppen und Systeme. Crimpen, löten, laminieren, umspritzen und Leiterplatten bestücken: Das tun viele – aber nur wenige vereinen all diese Techniken unter einem Dach. STAIGER bietet Ihnen diese wichtige Kombination! Wo an diese Techniken höchste Ansprüche gestellt werden, die Systeme immer komplexer, die Kombinationen immer vielfältiger und die Montagen immer aufwendiger werden, da kommen immer öfter wir ins Spiel.
Halbleiter Energieversorgungen

Halbleiter Energieversorgungen

Stromversorgungen für Induktionserwärmung & Schweißen Wir wissen, dass die Entwicklung der besten Stromversorgungen ein kritischer Aspekt bei der Herstellung innovativer Ausrüstung für die Induktionserwärmung ist. Unsere versierten Ingenieure erwägen bei der Auswahl der am besten geeigneten, technisch fortschritt-lichsten Komponenten während der Konstruktion sorgfältig alle Möglichkeiten und setzen ihre Erfahrung ein, um die idealen Leistungsanforderungen für Ihre Anwendung festzulegen. Inductoheat Europe liefert eine kostengünstige, zuverlässige Lösung für jede Leistungsanforderung, von fortschrittlichen Einzelsteuer-karten bis hin zu robusten Hochleistungs-Thyristoren, von der anfänglichen Auslegung bis hin zur endgültigen Fertigung. Neben dem umfassenden Service und Support, u.a. durch unsere Kundendiensttechniker und im Rahmen von Kundenschulungen, sowie kompletten schlüsselfertigen Systemen, sind wir perfekt aufgestellt, um als einzige Bezugsquelle für Ihren gesamten Bedarf im Bereich der Induktionserwärmung zu fungieren.
BaySpecial® NYKY-J 0,6/1 kV 4-5-adrig

BaySpecial® NYKY-J 0,6/1 kV 4-5-adrig

Bleimantelkabel speziell für Anlagen, bei denen mit der Einwirkung von Lösungsmitteln, Treibstoffen, Ölen, Benzin oder dergleichen gerechnet werden muss (z.B. in Tankstellen). Im Außenbereich, im Erdreich, speziell in Anlagen, wenn mit der Einwirkung von Lösungsmitteln, Treibstoffen, Ölen, Benzin oder dergleichen gerechnet werden muss (z. B. in Raffinerien oder Tankstellen). Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Aufgrund des flammwidrigen Mantels könnte es in die Brandklasse Eca eingestuft werden.
CableStore Kabelhalter

CableStore Kabelhalter

Kabelhalter aus stabilem Kunststoff. Artikelnummer: 411047 Breite: 4.2 cm Druckbereich: 25 x 25 mm Druckfarben: max. 4 Gewicht: 6 g Höhe: 0.3 cm Länge: 9 cm Maße: Maße: 9 x 4,2 x 0,3 cm. 6 g. Verpackungseinheit: 1000 Zolltarifnummer: 39269097
RJ45 Patchkabel 40G AWG 26

RJ45 Patchkabel 40G AWG 26

‧ voll-/paargeschirmtes 40G Patchkabel ‧ Kabeltyp: S/FTP 4x2xAWG 26/7 (PiMF) ‧ Kabelmantel: LSHF (LSOH), halogenfrei ‧ zwei robuste, geschirmte und multiportfähige RJ45-Stecker, Beschaltung 1 - 1 ‧ geschützter Verriegelungshaken ‧ Übertragungstechnische Eigenschaften Cat.8.1 nach ISO/IEC 11801 (bis 2000 MHz) ‧ Einhaltung der Klasse I nach ISO/IEC 11801, DIN EN 50173-1 ‧ 40GBASE-T geeignet für 40 Gbit Ethernet (IEEE 802.3bq) ‧ geeignet für Remote Powering (PoE, PoE plus, UPoE und 4PPoE) und HDBaseT geeignet ‧ Standardvarianten: 0,5 m, 1,0 m, 1,5 m, 2,0 m, 3,0 m, 5,0 m
HEJU Swing Lightning Ladekabel

HEJU Swing Lightning Ladekabel

Quasi-Zwilling des beliebten USB-Sticks „Swing“: Ladekabel mit Lightning-Anschluss. Artikelnummer: 950529-0 Druckbereich: 12 x 6 mm Gewicht: 5 g Maße: 67 x 12 x 5.5 mm Verpackung: Kartonbox mit Fenster
RE-Y(St)YSWAY-fl

RE-Y(St)YSWAY-fl

INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 2MULTİ-CORE, PVC INSULATED, COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 0,75 mm2 flexible, or, 1,5 mm2 stranded Insulation: PVC compound, TI1, BS 6746 Core identification: Up to 40 cores; yellow with black numbers and, word printed (1-40), (10,TEN); up to 80 cores;, black with yellow numbers and word printed, (1-40), (10,TEN) Lay-up: Cores laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PVC compund, TM1, BS 7655, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 2 Type 2 Insulation thickness: 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 39,0 Ω/km, 0,75mm2 : 26,0 Ω/km, 1,5mm2 : 12,1 Ω/km Insulation resistance: Min. 25 MΩ.km Mutual Capacitance: max. 250 pF/m Capacitance unbalance: (1 kHz) : max. 450 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
Consulting für Informationstechnologie

Consulting für Informationstechnologie

DBArt GmbH bietet umfassende IT-Beratungsdienste an, um Unternehmen dabei zu unterstützen, ihre Informationstechnologie optimal zu nutzen, ihre Geschäftsprozesse zu optimieren und ihre Wettbewerbsfähigkeit zu stärken. Mit einem erfahrenen Team von IT-Beratern und einem ganzheitlichen Ansatz bieten wir maßgeschneiderte Lösungen an, die genau auf die individuellen Anforderungen und Ziele unserer Kunden zugeschnitten sind. Unsere Herangehensweise Unsere Herangehensweise an die IT-Beratung basiert auf einem tiefen Verständnis für die geschäftlichen Herausforderungen unserer Kunden sowie auf einem breiten Spektrum an Fachwissen und Erfahrung in verschiedenen Branchen. Wir arbeiten eng mit unseren Kunden zusammen, um ihre aktuellen Situationen zu analysieren, klare Ziele zu definieren und eine maßgeschneiderte IT-Strategie zu entwickeln, die ihre geschäftlichen Ziele unterstützt. Leistungen Unser Leistungsspektrum im Bereich IT-Beratung umfasst: IT-Strategieentwicklung: Wir unterstützen unsere Kunden bei der Entwicklung einer umfassenden IT-Strategie, die ihre Geschäftsziele unterstützt und eine klare Roadmap für die Nutzung von Informationstechnologie bietet. IT-Infrastrukturberatung: Wir bieten Beratungsdienste zur Planung, Implementierung und Optimierung von IT-Infrastrukturen, einschließlich Netzwerke, Server, Speicher und Cloud-Computing-Lösungen. Softwareauswahl und -implementierung: Wir unterstützen unsere Kunden bei der Auswahl und Implementierung von Softwarelösungen, die ihren geschäftlichen Anforderungen entsprechen und einen echten Mehrwert bieten. IT-Sicherheitsberatung: Wir bieten umfassende Beratungsdienste zur IT-Sicherheit, einschließlich Risikobewertung, Sicherheitsrichtlinien, Incident Response und Compliance. Projektmanagement und -implementierung: Wir unterstützen unsere Kunden bei der Planung und Umsetzung von IT-Projekten, um sicherzustellen, dass sie termingerecht und im Rahmen des Budgets abgeschlossen werden. Warum DBArt GmbH? Erfahrung und Expertise: Mit über 20 Jahren Erfahrung in der IT-Branche und einem erfahrenen Team von IT-Beratern verfügen wir über das Fachwissen, um Ihnen erstklassige Beratungsdienste anzubieten, die Ihren geschäftlichen Anforderungen entsprechen. Kundenzentriertheit: Ihre Zufriedenheit steht für uns an erster Stelle. Wir arbeiten eng mit Ihnen zusammen, um sicherzustellen, dass unsere Lösungen Ihren Erwartungen entsprechen und echten Mehrwert bieten. Innovation und Fortschritt: Wir sind bestrebt, stets auf dem neuesten Stand der Technik zu bleiben und innovative Lösungen anzubieten, um Ihren geschäftlichen Erfolg zu unterstützen und zu fördern. Kontaktieren Sie uns gerne, um mehr über unsere Dienstleistungen zu erfahren und um Ihre Anforderungen zu besprechen!
HEJU Spider Ladekabel

HEJU Spider Ladekabel

In dieser stylischen Kugel befinden sich alle Kabel die Sie zum Aufladen Ihrer Geräte benötigen. Ob Mini-USB, Micro-USB oder Dock-Connector - Alles ist dabei! Artikelnummer: 1090988-2 Druckbereich: 25x15mm Gewicht: 33g Maße: 50 x 50 x 50 mm Verpackung: Blister
Kabelkonfektion

Kabelkonfektion

Wir konfektionieren Kabel passend Ihren Angaben und Vorschriften Individuelle Kabelkonfektion nach Ihren Anforderungen und den gesetzlichen Normen setzten wir in höchster Qualität um. Sie wählen aus mehr als 150 vorrätigen Kabelarten aus, wir verarbeiten diese mit modernsten Werkzeugen und Methoden. Wir bieten folgendes Leistungsspektrum an: - Konfektion von Einzeladern/Litzen, Flach- und Rundkabel, Sonderleitungen, Koaxialkabel, Motorenkabel, Steuer- und Signalleitungen - Konfektion kompletter Draht- und Kabelsätze (Querschnitten bis 120mm², weitere auf Anfrage) - Kundenspezifische Lieferung von Kabel- und Drahtsätze: Gebündelt, beschildert und nach Installationsprozess kommissioniert - Auslegung und Aufbauplanung mit Materialbeschaffung (gesamt oder teilweise) - Keine Lagerkosten durch Just-in-Time-Lieferung - Elektrische Prüfung aller Kabel mittels Testcomputer
Kabelkonfektion

Kabelkonfektion

K + B konfektioniert Kabel und Leitungen nach Ihren Vorgaben. Viele handelsübliche Kabel und Leitungen sind bei uns bevorratet und können mit einer Vielzahl von Kontaktmitteln (Kabelschuhen, Ringösen, Steckhülsen, Steckschuhen …etc.) angeschlagen werden. Nicht vorhandene Teile werden kurzfristig und kostengünstig beschafft. Leitungen mit komplettiertem Stecker jeglicher Art sind kein Problem. Wir verarbeiten hauptsächlich Leitungen von 0,25 – 2,5mm². Es können aber auch Leitungen mit größeren Querschnitten bearbeitet werden. Nehmen Sie Kontakt zu uns auf und informieren Sie sich über konfektionierte Kabel, Steuerkabel und Leitungen!
BayCom® nicht brennbar Metro OFC (metallfrei)

BayCom® nicht brennbar Metro OFC (metallfrei)

Metall- und halogenfreie sowie hochflammwidrige Lichtwellenleiter zum Fernsprechen und zur Datenübertragung für den Einsatz in Bereichen mit hohen Anforderungen an den Brandschutz. BayCom® nonfire B2ca Metro OFC sind metall- und halogenfreie sowie flammwidrige Lichtwellenleiter zum Fernsprechen und zur Datenübertragung für den Einsatz in Bereichen mit hohen Anforderungen an den Brandschutz. Die sehr guten Brandeigenschaften sorgen in Verbindung mit der UV-/Witterungsbeständigkeit, Erdverlegbarkeit und leichten Ölbeständigkeit für einen nahezu universellen Einsatzbereich. Zur Erleichterung der Montage sind Reißfäden integriert. BayCom® nonfire B2ca Metro OFC sind geeignet für: - Verlegung in Bauwerken mit hohem Brandsicherheitsbedarf (z.B. Tunnel, Fluchtwege), Schutz von Personen und hochwertigen Investitionsgütern - Feste Verlegung in trockenen und feuchten Räumen - Verlegung im Freien durch Bayka Soil Technologie, UV- und Ozonbeständigkeit getestet - Verlegung direkt in Erde durch Bayka Soil Technologie, EN ISO getestet
BayEnergy® N2X2Y-O  0,6/1 kV vieladrig

BayEnergy® N2X2Y-O 0,6/1 kV vieladrig

Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den HDPE-Außenmantel besonders widerstandsfähig. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
individuellen Spezialkabel

individuellen Spezialkabel

Spezialkabel oder Sonderleitungen sind Typen von Kabeln, die nicht genormt sind oder keiner Norm entsprechen. Schon jetzt bieten wir Ihnen eine umfassende Standardpalette an Kabelkonfektionierungen an. Darüber hinaus profitieren Sie von unseren individuellen Kabellösungen mit Sonderleitungen. Durch unser umfassendes Kabel Know-How sind wir Ihr zuverlässiger und kompetenter Partner, bei der Konfektionierung von Spezialkabeln. Außergewöhnliche Anwendungen und Nischenprodukte sind für uns deshalb kein Problem – wir finden die richtige kundenindividuelle Lösung für Sie. Von Beginn an sind unsere Mitarbeiter der Haas Kabeltechnik Ihr Helfer und Unterstützer bei der Produktfindung. Projektbegleitend stehen wir Ihnen jederzeit gerne zur Verfügung. Anhand von Ihrem vorgefertigten Muster oder Ihrer technischen Zeichnung wird ein individuelles Angebot erstellt. Falls Sie Hilfe bei der Realisierung eines Musters von Spezialkabeln brauchen, stehen wir Ihnen natürlich gerne beratend zur Seite.
BayEnergy® NYY-O 0,6/1 kV vieladrig

BayEnergy® NYY-O 0,6/1 kV vieladrig

Starkstromkabel für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze, falls kein erhöhter mechanischer Schutz erforderlich ist (siehe DIN VDE 0298-1). Im Innen- und Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist (siehe DIN VDE 0298-1). Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
Industrie-Patchkabel RJ45 Cat.6A PUR

Industrie-Patchkabel RJ45 Cat.6A PUR

Geschirmte PUR-Leitung zur sicheren und industrietauglichen Datenübertragung in der Automatisierungs- und Feldbustechnik. Die Leitung erfüllt die Forderungen nach ULStyle 20963 und erfüllt die Vorgaben nach Cat7 (elektr. Eigenschaften in Anlehnung an EN50288-4-2). Die Materialien und der konstruktiver Aufbau ermöglichen erhöhte mechanische Beanspruchung (Abrieb, Biegung, Erschütterung etc.) der Leitung. Besondere Eigenschaften: UL-Style 20963, seewasserbeständig, recyclefähig, LABS-frei, RoHs-konform, säure- und laugenbeständig, UV-beständig, hydrolysefest, halogenfrei, ölbeständig, hohe Flexibilität, keine korrosiven Gase, mikrobenfest, keine Brandfortleitung. ‧ vollgeschirmtes RJ45 Patchkabel Cat.6A AWG 26/7 ‧ geeignet für 10 GBit Ethernet (IEEE 802.3an) ‧ Knickschutztülle gespritzt mit integriertem Rasthebelschutz ‧ Kabelmantel PUR ‧ Standardvarianten: 0,3 m, 1,0 m, 2,0 m, 5,0 m, 10,0 m. ‧ Andere Längen auf Anfrage