Finden Sie schnell testers für Ihr Unternehmen: 150 Ergebnisse

TPT9000 Transformer Polarity Tester

TPT9000 Transformer Polarity Tester

Fast polarity testing of both voltage and current transformers. Compact and light Easy to use, plug & play Smart detection of incorrect connection Proving unit included in the kit as standard Fused lead sets included for user safety Supplied in a protective case. Long battery life Built in battery monitor The TPT9000 Transformer Polarity Tester is used for determining the correct polarity of current and voltage transformers. This device is a smart plug and play instrument designed for Commissioning Engineers. A lightweight instrument it comes with magnetised back panel, making it for storage on metallic walls or panels. TPT9000 automatically detects if the transformer has been connected incorrectly. The device comes with a proving unit to check the correct operation of the unit in the field. A set of 600V CAT IV fused test leads terminated in shrouded 4mm connectors is also included with the unit, along with 4 F500mA HRC fuses. The instrument is designed to be used on ‘dead’ systems (i.e., no externally supplied voltages are present on the test object). We strongly advise you not to connect the TPT9000 to a live system. Always make sure that the power of the device under test is off. TPT9000 Transformer Polarity Tester is designed for use in industrial and electrical substation environments on altitude level of maximum 2000m above sea level. Operating temperature is between 0°C and 45°C, while storage temperature is -20°C to 60°C. TPT9000 requires a single PP3 9V battery to operate. Battery level is automatically monitored, and the device will not perform a test if the battery voltage is below a useable level. WEIGHT 0.6 kg DIMENSIONS 118 × 79 × 32 mm SUPPLIED ACCESSORIES Proving unit 1 off 1m Black fused lead 1 off 1m Red fused lead 1 off 1m Blue fused lead 1 off 1m Brown fused lead Operating & Maintenance Manual Unit carry set case 9V battery OPTIONAL ACCESSORIES/SPARES Proving Unit, Part No. 249-0001 Complete replacement output lead set, Part No. A249-0002 Carry Case, Part No. A249-0003
18kV 10mA DC Tester PT18-10 MK2

18kV 10mA DC Tester PT18-10 MK2

Ultra lightweight (6.9kg) 1-200Adc test current with <2.5% ripple Supplied with standard 3m output lead set 0.1μΩ resolution mV, A, and m/μΩ displayed simultaneously USB memory key for data storage USB keyboard for comment entry Pre-settable test current with three buttons to store user test currents Large back-lit liquid crystal display Universal supply voltage 90-264V Optional current clamp to allows testing of objects with both sides earthed The PT18-10 mk2 high voltage dc test set is designed to perform tests on installed cable and jointing systems. The 18kV 10mA DC Tester has a variable output voltage with a maximum of ±18kVdc with a maximum charging capability of 10mA. A zero-volt interlock is fitted that prevents the output being switched on unless the output control is at zero. Units include an automatic load discharge system that discharges the cable under test when the output is switched off or a breakdown occurs. Internal dumping system can discharge a maximum of 2.5kJ on each output, corresponding to 10µF at 18kV. In the event of a test object failure, the overload circuit will automatically switch off the output voltage and earth the output via the internal discharge circuit. A DP20 discharge probe is supplied as standard with the PT18-10 mk2, 18kV 10mA DC Tester, allowing higher load capacitances to be safely discharged. The 18kV 10mA DC Tester has an internal fail-safe automatic discharge system with the following ratings: Max. discharge voltage (kVdc) 20kVdc Highest discharge energy 2.5kJ Highest discharge capacitance 10μF Max. discharges per hour 4 The automatic discharge switch is controlled by a solenoid. It may produce a noticeable hum when the HT output is energised. Output voltage is metered by two large, linear, analogue instruments marked 0-20kV. Meanwhile, current is metered by two further analogue instruments with 0-10 scale marking. The meters read 0-10mA directly, or 0-1mA when the ÷10 push button is operated. The HV output from the unit uses a high quality plug and socket system, allowing for easy cable replacement. High voltage plugs are protected in transit by plastic covers and are fully de-mountable. Screened 5 metre long high voltage output cables are provided with the equipment terminated with large clips. The mk2 units introduce automatic 115/230V mains voltage selection. That along the padded bag ensure maximum protection during transit.
C.A 6108 Gerätetester

C.A 6108 Gerätetester

• Großformatiges Display mit hohem Kontrast • Schutzleiterwiderstandsmessung mit 200 mA und 10A Prüfstrom • Direkte Identifizierung der Prüflinge über Tastatur, Barcode- oder Transponderscanner • Stromzangenanschluss für die Prüfung von Geräten mit Festanschluss und Drehstromprüflingen über CEE-Adapter • Prüfung von Verlängerungsleitungen Standard oder mit RCD Typ A/B (Baustromverteiler) bzw. PRCD, PRCD-S, PRCD-K (Option) • Kaltgeräteanschluss- und Verlängerungsleitungen direkt prüfbar • Automatischer Prüfablauf mit Klartextanweisungen in Deutsch und Anschlusspiktogrammen • Gut-/Schlecht-Bewertung über LEDs (grün/rot) • Funktionstest mit Leistungsmessung in Echt-Effektivwert • Prüfungen nach DIN VDE 544-4 / IEC 6974-4 freischaltbar (Option) • Prüfung der Standby-Stromaufnahme nach EU-Verordnung 1275/28 (Option) • Datenspeicher für 100000 Messungen und 32 Kunden • Datenaustausch über USB-Stick und USB-Kabel • Datenbank-Software mit Upload der Stammdaten vom PC • Extrem robustes Gehäuse für den Feldeinsatz Der Gerätetester C.A 6108 dient zur Sicherheitstechnischen Prüfung von elektrischen Betriebsmitteln nach DIN VDE 0701-0702 bzw. ÖVE 8701 und DGUV Vorschrift 3 sowie von elektromedizinischen Geräten nach DIN VDE 0751-1 bzw. ÖVE 8751. Optional ermöglicht das Gerät ebenfalls die Prüfung von Lichtbogenschweißgeräten nach DIN VDE 0544-4. Auf dem großformatigen beleuchteten Display wird der Benutzer in jedem Prüfablauf sowohl durch eine Kontexthilfe im Klartext als auch durch Anschlussbilder geführt. Alle Ergebnisse werden mit Gut-/Schlecht-Bewertung angezeigt. Dank der vollwertigen QUERTZ-Tastatur und des großen internen Speichers können sämtliche Informationen über die Prüflinge und Bemerkungen zu deren Prüfergebnissen direkt vor Ort im Gerätetester hinterlegt werden. Bei der Prüfprotokoll-Erstellung ist somit eine lästige Nachbearbeitung nicht mehr erforderlich. Um ebenso Neueingaben bei Wiederholungsprüfungen zu vermeiden, besteht die Möglichkeit, Stammdaten in das Gerät zu übertragen. Sämtliche Informationen bzw. Messkonfigurationen zum Prüfling können somit direkt oder mit Hilfe eines Barcode- oder Transponderscanners aufgerufen und erneut verwendet werden. Alle Messungen erfolgen über nur eine Steckdose und eine Messsonde mit vollautomatischer Leitungskompensation. Eine zusätzliche Kaltgerätesteckdose steht für eine direkte vollständige Prüfung von Kaltgeräteanschluss- und Verlängerungsleitungen – Standard oder optional mit RCD Typ A/B bzw. PRCD, PRCD-S, PRCD-K – zur Verfügung. Diverse Verlängerungsleitungsadapter für unterschiedliche Drehstromsysteme (16, 32, oder 63A) sind ebenfalls erhältlich. Mit Hilfe einer als Zubehör lieferbaren Stromzange, lassen sich Ableitströme direkt an fest angeschlossenen Geräten messen ohne diese abklemmen zu müssen. Für die Messung von Ableitströmen an Drehstromprüflingen werden diverse geeignete Messadapter angeboten. Um den Stromfressern im Bereitschaftsbetrieb auf die Spur zu gehen, besteht die Möglichkeit, auf Wunsch eine Standby-Strom- und -Leistungsmessung nach der EU-Verordnung 1275/2008 freizuschalten. Der Gerätetester C.A 6108 verfügt über einen großen internen Speicher für 100000 Messungen sowie eine USB-Schnittstelle zum bidirektionalen Datenaustausch mit einem PC über USB-Stick oder -Kabel. Die extrem einfach zu bedienende PC-Software C.A Appliance „Standard“ bietet außer der Protokollerstellung unter anderem die Möglichkeit Stamm- und Prüfdaten automatisch in Standard-Formaten (Microsoft Word™ und Excel™) zu verwalten und archivieren. Folgende Mess- und Prüffunktionen stehen zur Verfügung: • Schutzleiterwiderstandsmessung bis 4,000 Ω • Isolationsmessung bis 20,00 M Ω • Differenzstrommessung bis 20,00 mA • Ersatzableitstrommessung bis 40,00 mA • Patientenableitstrommessung bis 4,000 mA • Ersatzpatientenableitstrommessung bis 4,000 mA • Berührungsstrommessung bis 4,000 mA • Strommessung bis 20,0 A • Strommessung über Zange bis 40,00 A • Spannungsmessung bis 260,0 V • Leistungsmessung bis 4000 W • Standby-Strommessung bis 40,00 mA • Standby-Leistungsmessung bis 500 mW • Leerlaufspannungsmessung bis 350,0 V
PCU1-SP MK2 Primary Current Injection Test Set

PCU1-SP MK2 Primary Current Injection Test Set

5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switching 200A, 2000A and 5000A loading units Three range outputs on loading units Rugged, compact design Optional trolley mounting of system Secondary injection up to 100A Auxiliary metering input Direct reading CT ratio and polarity The PCU1-SP mk2 is a medium powered primary current injection set offering output currents up to 5000A (11.5kVA for 40seconds). The system consists of a separate control unit containing all metering and control functions and a loading unit, such as the NLU200, NLU2000 or the NLU5000, that provides the high current output. The PCU1-SP mk2 are ideally suited to primary current injection, stability testing and circuit breaker testing. In addition, the SP version offers direct-reading CT ratio and polarity tests and a 100A secondary injection output. Two loading units are available, delivering a maximum output current of 2000A or 5000A. Each loading unit has three output taps to allow for a wide range of load impedances. For example, the NLU5000 may be configured to either give a maximum current of 5000A on the 2.3V range, 2500A on the 4.6V range or 1250A on the 9.2V range. *The above is an image of the PCU1-SP and Loading Unit The control unit is rated at 11.5kVA with a 2 second overload capability of 23kVA using pulse mode. All metering is digital and a memory facility is provided to hold the current reading when the output trips or is switched off. The current is switched by a solid state device and is automatically switched off when the device under test trips. The PCU1-SP systems have a high accuracy timing system, allowing timing tests to be carried out to a resolution of 1ms. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available to test under and over current devices, re-closers, under and over voltage devices, current trips and circuit breakers. A full range of high current output leads are available to complement the system in a range of lengths. WEIGHT 26 kg DIMENSIONS 450 × 275 × 305 mm SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse set OPTIONAL ACCESSORIES Trolley mounting system, Part no A204-0005 100ADM-F, Part no. 006 100AL MK2 / MK3 Lead Set, Part no. A199-0003
TDX 5000 Tan Delta and capacitance test set

TDX 5000 Tan Delta and capacitance test set

TDX 5000 is developed as a compact solution for high voltage Capacitance and Tan Delta (Dissipation Factor) measurements. Using the reactor option, TDX 5000 can also perform tests on rotating machines. Main features Fully automatic Variable output frequency: 1 – 500 Hz Output voltage up to 12 kV Tan Delta, capacitance, dissipation factor measurements and exciting current test RCTD – compensating reactor module allows increasing the test current and getting the maximum test voltage with high capacitive burdens PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report USB interface and Ethernet interface for PC connection Patented technology for capacitance and Tan Delta measurement Light and compact Tests performed Tangent Delta Capacitance
200ADM-P Secondary Current Injection Test Set

200ADM-P Secondary Current Injection Test Set

The 200ADM-P is a current injection system with a wide range of advanced features including phase shift, data storage and harmonic analysis. 0-200A output current True RMS metering with 1 cycle capture Variable auxiliary ac voltage/ current output with phase shift Auxiliary metering input V, f, Φ, Z, P, S, PF, CT ratio, harmonics & more Variable auxiliary output 12-220Vdc Multi-function auto-ranging timing system Current limit mode for fine control Data storage to USB memory key including waveform & harmonics USB keyboard/printer interface Automatic mains voltage selection The 200ADM-P Secondary Current Injection Test Set has a range of outputs allowing injection of currents between 1mA and 200A. Voltages up to 240V are available on the main outputs allowing high impedance current relays to be tested. True RMS metering with single cycle capture is provided. 4 current ranges allow the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used throughout for safe, reliable convenience. The 200ADM-P Secondary Current Injection Test Set has a flexible auxiliary ac output that can be used at up to 260V for voltage relays or up to 10A for current relays. The phase and frequency of this output are fully adjustable. This combination of voltage and current allows testing of relays that require two voltages, one voltage and one current or two currents. An auxiliary metering module is provided that meters ac and dc voltage, current and frequency from the auxiliary outputs or external signals. The module can also take measurements in conjunction with the main current output to meter phase angle, power, impedance, CT ratio and harmonics. A variable stabilised DC supply with current limit is provided to power the relay under test. WEIGHT 22.6 kg DIMENSIONS 500 × 456 × 265 mm SUPPLIED ACCESSORIES Operating manual Output lead set Mains lead Sparefuses USB keyboard USB memory key Shoulder strap (except Pelicase unit) OPTIONAL ACCESSORIES 100ADM-F, Part no. 006 100AL Mk2 / Mk3, Part no. A199-0003
KV50-200 MK3 Test System

KV50-200 MK3 Test System

0-50kV output voltage 5kVA output capability Key operated supply switch to prevent unauthorised operation Dual overload protection Variable electronic trip – 10-110% of rated output Voltage and current metering External interlock circuit Zero-volt interlock Visual indication of test piece failure The KV50-200 MK2 Test System is a high power, high voltage ac test set designed for insulation testing. This system is equally suited to both development and routine testing of electrical insulation systems and plant. The equipment consists of a control unit and a separate oil filled high voltage transformer, linked by 5 meter supply and control cables. The control unit is fitted with a comprehensive range of facilities for control, metering and protection. The system includes a secondary tap metering as standard to ensure accurate voltage metering. The output voltage and current are displayed on large, linear analogue instruments, and a variable electronic trip is provided, allowing the trip current to be set to 10-110% of rated output. The high voltage transformer is housed in an oil-filled steel tank fitted with swivel castors for mobility. The units use a low-discharge oil-filled bushing for the HV output. The KV50-200 MK2 Test System is equally suited to testing capacitive, resistive or inductive test objects. The output of the units are protected by variable electronic trips monitoring the output current, and a fixed over-current trip on the primary of the output transformer. The variable trip is adjustable in 10% steps between 10% and 110% of the rated output current. The input and control supplies are protected by fuses. An earth terminal is provided on the transformer which must be connected to a low impedance local earth. WEIGHT 37 kg DIMENSIONS 370 × 480 × 290 mm TRANSFORMER WEIGHT 220 kg TRANSFORMER DIMENSIONS 570 x 500 x 1020 mm SUPPLIED ACCESSORIES Supply lead Spare fuse set Operating manual Earth lead
100ADM MK5 Secondary Current Injection Test Set

100ADM MK5 Secondary Current Injection Test Set

0-100A output current True RMS metering with single cycle capture Auxiliary DC and AC output Multi-function auto-ranging timing system Current limit mode for fine control Automatic mains voltage selection Thermal and over-current protection The 100ADM mk5 Secondary Current Injection Test Set provides commissioning and maintenance engineers with a flexible system for testing protective systems. It has an easy to understand panel layout and a simple user interface. The status of every function can be seen at a glance, and there are no complex menus to navigate. The 100ADM mk5 keeps the familiar user interface of previous models but adds a new metering system that accurately measures the RMS of a single cycle. It also features a new current limit mode to provide very fine control of very low currents, even into low impedance loads. Current limit mode also assists in testing self-powered overcurrent protection as fitted to many 11kV ring main units. The unit has a range of outputs allowing injection of currents as low as a few mA and as high as 100A. Voltages up to 240V are available on the main outputs, allowing high impedance current relays and voltage relays to be tested. Four true RMS metering ranges are provided, allowing the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used on all inputs and outputs for convenience, reliability and safety. The 100ADM Mk5 Secondary Current Injection Test Set is comprehensively protected by overcurrent, duty cycle and thermal trips, and keeps the user fully informed of any trip condition. A stabilised DC supply is provided to power the relay under test, along with an independently switched and isolated 110V AC output. The back-lit display on the 100ADM mk5 is bright and clear with a wide viewing angle. The results of a test can be seen here as they appear on the display A very flexible two channel timing system is provided, allowing trip times, reset times and re-close times to be quickly measured to a high degree of accuracy. The timer auto-ranges to measure from 1ms to 99999.9s. The 100ADM can be used to test many types of single phase secondary protection including: 27/59 Over and under voltage relays 37 Under current 51 IDMT relays 50/76 Instantaneous overcurrent 59G Neutral voltage displacement 79 Auto-reclosers 2 Time delay relays 51G/50G Earth fault relays 67 Directional overcurrent (basic tests) 52 Miniature circuit breakers Tripping relays Thermal relays 90V Voltage regulating relays WEIGHT 23.9 kg DIMENSIONS 560 × 456 × 265 mm SUPPLIED ACCESSORIES Operating manual Mains lead Output lead set Spare fuses Carry strap OPTIONAL ACCESSORIES 100ADM-F, Part no. 006
TD 5000 Tan delta test set

TD 5000 Tan delta test set

The high-voltage generator TD 5000 is a complementary module of STS serie. TD 5000 designed to perform Tan Delta measurements, dissipation factor and capacitance of transformer and bushing at the frequency of the mains or in a wide frequency range. Main features Optional module for STS 5000 and STS 4000 test set, standard module for STS 3000 light Tan Delta, capacitance, dissipation factor measurements and for exciting current test Output voltage from 12 V up to 12 kV Variable output frequency: 1 – 500 Hz PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report Compact and lightweight Patented technology Tests performed Tangent Delta Capacitance Dissipation factor
KV30-100 MK3 Test System

KV30-100 MK3 Test System

0-30kV output voltage 3kVA output capability Key operated supply switch to prevent unauthorised operation Dual overload protection Variable electronic trip – 10-110% of rated output Voltage and current metering External interlock circuit Zero-volt interlock Visual indication of test piece failure The KV30-100 MK2 Test System is a high power, high voltage ac test system designed for insulation testing. This system is equally suited to both development and routine testing of electrical insulation systems and plant. The equipment consists of a control unit and a separate oil filled high voltage transformer, linked by 5 metre supply and control cables. The control unit is fitted with a comprehensive range of facilities for control, metering and protection. The output voltage and current are displayed on large, linear analogue instruments, and a variable electronic trip is provided, allowing the trip current to be set to 10-110% of rated output. The high voltage transformer is housed in an oil-filled steel tank fitted with swivel castors for mobility. The unit uses a high voltage bushing for the HV output, and the other end of the HV winding is earthed. The output of the units are protected by variable electronic trips monitoring the output current, and a fixed over-current trip on the primary of the output transformer. The variable trip is adjustable in 10% steps between 10% and 110% of the rated output current. The input and control supplies are protected by fuses. The KV30-100 MK2 Test System is equally suited to testing capacitive, resistive or inductive test objects. If higher voltage or output power is required, please refer to our KV50-200/KV100-100 data sheet, detailing our 10kVA high voltage systems. WEIGHT 25 kg DIMENSIONS 370 × 480 × 290 mm TRANSFORMER WEIGHT 210 kg TRANSFORMER DIMENSIONS 480 x 460 x 570 mm SUPPLIED ACCESSORIES Supply lead Spare fuse set Operating manual Earth lead
KV5-100 MK3 Test System

KV5-100 MK3 Test System

Continuously variable output voltage 0-5kVAC Variable trip circuit 12mA and 20-120mA Output voltage and current metering Visual and audible indication of test piece failure The KV5-100 MK3 Test System is a general purpose, high voltage test instrument designed for testing insulation systems and the measurement of breakdown voltage on electrical plant and components. The unit has an output voltage adjustable from zero to 5kV with accurate metering on both the output voltage and current. A zero-voltage interlock is provided, ensuring that the output may only be energised with the voltage control at zero. The output voltage is metered by a large, linear analogue instrument with a dual-scale marking of 0-3kV and 0-6kV. Load current is metered by a second analogue instrument with 0-10 scale marking. Two current ranges are selectable: 0-10mA and 0-100mA. The test object and output are protected by an adjustable current trip linked to the current metering range. The trip level may be set to 20-120% of the current metering range on 20% steps. Breakdown of the test object is both audibly and visibly indicated. The alarm must be manually reset after a trip condition before testing can be resumed. The KV5-100 MK3 Test System is supplied in a compact and portable case with permanently connected test leads. The test leads are terminated in crocodile clips. The unit is designed to be used in conjunction with an interlocked test enclosure. WEIGHT 16.5 kg DIMENSIONS 364 × 147 × 262 mm SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse
CU-Ps Primary Current Injection Test Set

CU-Ps Primary Current Injection Test Set

5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switching 200A, 2000A and 5000A loading units Three range outputs on loading units Rugged, compact design Optional trolley mounting of system Secondary injection up to 100A Auxiliary metering input Direct reading CT ratio and polarity The CU-Ps primary current injection test set is ideally suited to commissioning and maintenance testing where very high currents are required. The system consists of separate control and loading units for maximum flexibility. The control unit contains all control and metering circuitry, and is linked to the loading unit by control and metering cables. The control unit may be used with one of two loading units providing between 5000A or 6000A for 5 minutes or up to 10 or 12kA for short periods. Each loading unit has two outputs which may be connected in series or parallel for maximum flexibility. For example, the PLU-6k may be configured to either give a maximum current of 3000A at 6.6V or 6000A at 3.3V. The control and loading units are each housed in tough steel cases fitted with castors and protective lifting handles. The loading units have a small plan area to allow them to be positioned as close as possible to the test object, minimising power requirements and maximising the available current. The CU-Ps control unit is shown here with a PLU-6k loading unit. This combination may be used to inject currents of up to 6000A for 5 minutes or 12000A for 1 second. The CU-Ps primary current injection test set is ideally suited to all primary current injection tasks, including testing under and over current relays, circuit breakers and CT ratio testing. The control unit is rated at 20kVA and has digital metering. A memory facility is provided on the metering to hold the current reading when the output trips or is switched off. The current is automatically switched off when the device under test trips. The CU-Ps systems have a high accuracy timing system with 1ms resolution. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available for under and over current devices, reclosers, under and over voltage devices, current trips and circuit breakers. The AC output current is metered by a true RMS memory ammeter (acquisition time 20ms) with a liquid crystal display. The current metering has 3 ranges corresponding to 10%, 50% and 100% of the maximum rating of the loading unit. In addition, a 200% metering range is enabled in pulse mode for the 0.2s, 0.5s and 1s settings only. The CU-Ps systems have a flexible timing system with two contact inputs and 5 operating modes. Each contact circuit automatically selects for N/O or N/C contacts, and the status of each contact input is shown by an LED. The timing channels may also be triggered by a dc voltage between 24 and 240V. *Pulse mode applies current to the load for a maximum of the specified time. If contact set 1 changes state or the current drops below 20% of the metering range during the pulse time, the timer is stopped. The maximum output current is increased in pulse mode. The maximum obtainable current is set by the impedance of the test object and output leads. **Current operated mode is used to time circuit breakers with no auxiliary contacts. The timer is started when the current exceeds 20% of the selected metering range (e.g. 1000A on the PLU-5k 5000A range). The timer stops when the current falls. All test results from the CU-Ps can be stored in a USB memory key. The unit has a real-time clock to time and date-stamp all results. To log the results, first enter a comment for your results using the optional keyboard, and then select AUTO STORE. Whenever the timer stops, the time, current and all other parameters are added to a spreadsheet file on the USB key. You can then view the current set of results on the display or take the USB key out and open the file on your PC. All results are stored in a folder on the USB key named with the test date in a file named with the time. The CU-Ps primary current injection test sets and loading units are CE marked and are designed to meet the requirements of BS EN61010. The system is protected by electronic trips on the outputs, circuit breaker and fuse on the mains input, and a circuit breaker on the control unit output. The unit also has a duty cycle trip on the loading unit output and thermal protection. WEIGHT 115 kg DIMENSIONS 660 × 400 × 740 mm OPTIONAL ACCESSORIES A range of output lead sets are available to complement the CU-Ps system with current ratings between 3000A and 6000A. The leads are double insulated and have good flexibility. SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse set
QUICKLAN6055 Netzwerktester

QUICKLAN6055 Netzwerktester

Kabeltest bei geschirmtem (STP) und ungeschirmten (UTP) Kabeltypen mit RJ45-Verbinder Automatische Erkennung der externen Marker (#1 bis #8) Verkabelungskontrolle (Mapping) Low Bat Anzeige Datenblatt Bedienungsanleitung
HT Instruments GSC53N Multifunktions VDE 0100-Tester mit 3-Phasen Netzanalyse

HT Instruments GSC53N Multifunktions VDE 0100-Tester mit 3-Phasen Netzanalyse

Messung + Kontrolle nach VDE0100, VDE0105, EN61557 + EN50160. Multifunktionsprüfgerät inkl. 3 Phasen Netz- + Leistungsanalysator,Oberwellenermittlung, Spannungsqualitätsanalyse nach EN50160 Messfunktionen und technische Merkmale: Große übersichtliche LCD Anzeige mit Hintergrundbeleuchtung Niederohmmessung mit > 200mA DC (VDE 0413 Teil 4, EN 61557-4) Isolationsprüfung mit 50,100,250,500 oder 1000V DC (VDE 0413 Teil 2, EN 61557-2) Komplette FI (RCD) Test und Analysefunktion (VDE 0413 Teil 6, EN 61557-6) Schleifen- und Netzimpedanzmessung (VDE 0413 Teil 3, EN 61557-3) Anzeige des Kurzschlußstromes Ik (VDE 0413 Teil 3, EN 61557-3) Schleifenwiderstandsmessung ohne Auslösung des FI Drehfeldrichtungsmessung (VDE 0413 Teil 7, EN 61557-7) Erdungsmessung und spez. Erdwiderstandsmessung (VDE 0413 Teil 5, EN 61557-5) Spannungsqualitätsüberwachung (EN50160) Netzanalyse & Leistungsmessung, Energieverbrauchsanzeige Oberwellenermittlung und Scope-Funktion Integrierte optische Schnittstelle auf USB Anschluss für 3 externe Stromzange 1mA bis 3000A Anschluss für externe Messsonden zur Feuchte-, Temperatur-, Licht und Schallpegelmessung Interner Meßwertspeicher für 800 Messwerte bzw. 2MB für Langzeitmessung Automatische Abschaltung Integriertes Gummi-Schutzholster Sicherheit nach IEC-1010-1, CAT III 415V Prüfung der Netzqualität nach EN50160 Das Modell GSC53N ermöglicht neben der VDE0100 Messung auch eine vollständige Überprüfung der Netzqualität an Ein- und Dreiphasensystemen, sowohl bei symmetrischer als auch unsymmetrischer Belastungen. Folgende Parameter können ermittelt werden: Spannungsschwankungen über die eingestellten Grenzwerte (Einbrüche und Spitzen) mit 10ms- Mindestauflösung Spannungsverlauf TRMS bis 600V Stromverlauf TRMS bis 3000A Oberwellen von Spannung und Strom bis zur 49. Ordnung Wirkleistung, Blindleistung, Scheinleistung Energieverbrauch Leistungsfaktor cos Bei einem Intervall von 15min und 63 ausgewählten Kanälen beträgt die Aufzeichnungskapazität mehr als 30 Tage.
HT Instruments JUPITER,  VDE0100 Tester & Multimeter TRMS

HT Instruments JUPITER, VDE0100 Tester & Multimeter TRMS

VDE0100 Tester - CAT IV 600V mit TRMS Multimeterfunktion Das erste Multimeter mit Funktionen, die nur in Standard-Sicherheitstestern und professionellen High-End-Multimetern verfügbar sind. •Jupiter ist das einzige Multimeter, das auch die Sicherheit der elektrischen Installation überprüfen kann. •Es vergleicht die Messung mit den vorgegebenen Grenzwerten und zeigt ein klares OK / NOT OK an. •Die Funktionen von Jupiter sind für gewöhnlich nur in high-end Messgeräten integriert. •An mir können unterschiedliche externe Stromwandler zur Messung von AC TRMS, DC, AC+DC, und Einschaltströmen angeschlossen werden. •Ich bin handlich, sehr robust und kompakt •Autorange Messungen mit automatischer AC/DC Erkennung •DC,AC TRMS, AC+DC TRMS bis 690V •LoZ Spannungsmessung mit geringer Eingangsimpedanz •DC, AC TRMS, AC+DC TRMS Strom mit Hilfe eines externen Wandlers •Frequenz von Spannung und/oder Strom •Widerstands- und Durchgangsprüfung mit Summer •MIN/MAX/PEAK/HOLD Funktionen •Anzeige mit 6000 Punkten
MULTISAFE DSP5 – Profi-Spannungsprüfer für höchste Anforderungen.

MULTISAFE DSP5 – Profi-Spannungsprüfer für höchste Anforderungen.

Der MultiSafe DSP 5 ist das sichere, einfach zu bedienende Prüfwerkzeug für alle Bereiche der Industrie- und Energietechnik. Er kombiniert höchste Sicherheit CAT IV – 1000 V, leichte Bedienung und Multimeter-Präzision in einem Spannungsprüfer. Der Spannungsprüfer erfüllt alle Anforderungen an ein modernes, sicheres Prüfmittel und ist mit seinem großen Funktionsumfang auch für zukünftige Aufgaben gewappnet. Der MultiSafe stellt sich automatisch ein/um/aus. Spannungsprüfer: präzise Anzeige der Spannung 0,3 V bis 1200 V AC /0,01 bis 1500 V DC erweiterter Prüfbereich für Klein- und Batteriespannungen 0,01 bis 19,99 V DC extrem Spannungsfest – CAT IV 1000 V – VDE zertifiziert große zweifarbig beleuchtete Anzeige (rot/weiß), zur deutlichen Warnung vor gefährlichen Spannungen eindeutige LED-Anzeige für gefährliche Spannung Lastzuschaltung für Störspannungen und RCD-Auslösung Halten des Messwertes durch HOLD-Taste Durchgangsprüfer: schneller Durchgangstest mit Ton genaue Widerstandsmessung im Bereich 0,01 kOhm bis 1000 kOhm grüne LED für Durchgang Phasen- und Drehfeldrichtungsprüfer: Phasenprüfer mit Anzeige “POL” und roter LED Drehfeldprüfer mit LCD und LED Anzeige rechts / links Controller-überwachte Prüfung mit Fehlererkennung zur Vermeidung von Falschaussagen Phasen- und Drehfeldrichtungsprüfer können mit Handschuhen genutzt werden zusätzlicher Drehfeldprüfer ohne Erdbezug für IT-Netze weitere Funktionen: Messstellenbeleuchtung schlanke Prüfelektroden für enge Klemmleisten Einhandbedienung beim Prüfen von Steckdosen leichte Bedienung Isolierungsfehler Erkennung durch zweifarbige Leitungsisolierung extrem stabiles Gehäuse, auch bei Kälte IP 65 – wasserdicht rückseitig mit Gürtelclip
C.A 6121 – Maschinentester gemäß EN 60204

C.A 6121 – Maschinentester gemäß EN 60204

Spannungsprüfung: 1000, 1250 und 1500 V AC mit:- Einstellung der max. Stromschwelle – Anzeige der tatsächlichen Spannungs- und Stromwerte – mit oder ohne Zeitgeber – Schwimmende Hochspannungsausgänge für höhere Sicherheit Isolationsprüfung: 0 bis 500 MΩ 500 oder 1000 V DC mit:- Programmierung eines Mindestwiderstandswerts – mit oder ohne Zeitgeber Durchgangsprüfung: 0 bis 2Ω 12 V / >10 A AC mit:- 4-Leiter-Messung – Anzeige des Spannungsabfalls (ΔU: 0 bis 10 V – Programmierung eines max. Spannungsabfalls und eines Widerstandswerts – mit oder ohne Zeitgeber Prüfung der Entladezeit: 0 bis 10 s bei 600 V AC/DC – 2-Punkt-Messung (Netzanschluss) oder 4-Punkt-Messung (Bauteile) Beleuchtete LCD-Anzeige Speicher: 1.000 Messungen RS232-Ausgang Signale per Fernbedienung Software / Fußschalter für Bediendung mit Abstand / Warnlampen und Drucker als Lieferoption Gerätekoffer mit IP54 Messungen gemäß EN 60204-1, VDE 104 und EN 61180-1 und -2 Überspannungsschutz: IEC 1010 CAT III 600 V Abmessungen: 250 x 260 x 400 mm; Gewicht: 11 kg Das robuste und tragbare C.A 6121 ist das ideale Prüfgerät zur Maschinen-Richtlinie EN 60204, da mit ihm alle vorgeschriebenen Messungen durchgeführt werden können.
MultiSafe DSP TT1 Teleskopspannungsprüfer , DC / 15 – 500 Hz

MultiSafe DSP TT1 Teleskopspannungsprüfer , DC / 15 – 500 Hz

MultiSafe DSP TT1 / DC / 15 – 500 Hz: Teleskopspannungsprüfer zur schnellen Spannungsprüfung an Bahnoberleitungen und Freiluftschaltanlagen Vergossene Schutzwiderstände direkt hinter der Prüfelektrode und der integrierte Eigentest bieten höchste Sicherheit. Der MultiSafe stellt sich automatisch ein/um/aus und ist sehr einfach zu bedienen. Pluspunkte • präzise Anzeige von Spannung ab 50 V • Oberleitungs-Prüfhöhe bis 6,2 m oder 8,2 m • höchste Sicherheit durch vergossene Schutzwiderstände direkt in der Prüfspitze, max. Strom < 3,2 mA • einfach Bedienung mit nur einer Taste, Eigentest zur Überprüfung von Funktion, Schutzwiderständen und korrekter Erdungsverbindung Der MultiSafe DSP TT1 ist ein zweipoliger Teleskop-Spannungsprüfer für Spannungen bis 1000 V AC / 1500 DC. Er ist geeignet, um die Spannung an nicht isolierten Oberleitungen (Fahrdraht) oder unisolierten Stromschienen gegen Erde (Schiene) schnell und sicher festzustellen. Der DSP TT1 ist zur Verwendung für Innenraumanlagen und Außenanlagen zugelassen. Die Spannung wird durch eine rote LED signalisiert und der Wert digital auf dem LCD angezeigt. Mit dem Eigentest wird die Funktion des Prüfers und die Erdverbindung einfach und schnell überprüft. Bereitschaft und nicht vorhandene Spannung wird durch eine grüne LED angezeigt.
HT Instruments GSC60, VDE0100 Installationstester

HT Instruments GSC60, VDE0100 Installationstester

VDE0100 Installationstester & 3 Phasen Netz-/ Energieanalysator CAT IV mit Farb-Touchscreen und WLAN Elektroinstallationen gemäß VDE 0100 / VDE 0105 prüfen: Ein Messgerät für alle elektrischen Sicherheitstest gemäß VDE 0413 (EN61557) Teil 2, 3, 4, 5, 6 und 7 Schutzleiter-Durchgangsprüfung mit >200 mA Prüfstrom Isolationsmessung mit 50 / 100 / 250 / 500 und 1000 V DC RCD Test Typ A, AC und B, B+, F Netz- & Schleifenimpedanz mit Ik Anzeige Schleifenimpdanz ohne RCD Auslösung Drehfeldrichtungsermittlung (Phasenfolge) Messung des Spannungsfalls dV in % Erdungsmessung mit 2- oder 3-Leiter Methode Erdungsmessung (ohne Hilfserder) mit T2100 (optional) Erdwiderstandsmessung mit 4-Leiter Methode Messung von Lichstärke und Temperatur** Leckstrommessung ab 1mA*** ** mit optionaler Sonde HT52 / HT53 *** mit optionaler Stromzange HT96U Analyse von Netzqualität und Energieverbrauch: 9 voreingestellte Netzsysteme stehen zur Auswahl (Stern / Dreieck / 1-2 oder 3 Phasen etc) Mehr als 383 Parameter können über 2 Monate aufgezeichnet werden Echtzeit-Anzeige als Wellenform (Scopefunktion), Harmonische, Vektordiagramme sowie eine numerische Darstellung für eine schnelle Überprüfung der wichtigsten Parameter Spannungsanomalien-Analyse mit einer Auflösung von 20 ms Energiekostenkontrolle. Mit nur einem Klick überprüfen Sie den Energieverbrauch mit Hilfe der an der Hauptstromversorgung angeschlossenen Stromwandler und managen so die Energiekosten Weltweite Verbindung: Dank der integrierten Wi-Fi Funktion können Sie Ihre Messdaten einfach und bequem über unsere App HTANALYSIS™ versenden. Überprüfen Sie online Ihre Messergebnisse und speichern Sie die Daten in der HTCloud™ oder versenden Sie diese per E-Mail. Zu jeder Zeit volle Batterien: Das kompakte GSC60 wurde mit der neuen Power-Technologie ausgestattet, um die Batterien in kürzester Zeit zu laden. Verbinden Sie das externe Netzteil einfach mit dem Gerät und der Stromversorgung, um die Batterien zu laden. Haben Sie keine Zeit zum Warten, so verwenden Sie einfach die Standard AA Batterien. HTOS™ – Energie managen: Über den Touchscreen können Sie einfach und intuitiv die gewünschte Energie-Messung auswählen. Nehmen Sie die gewünschten Einstellungen im geführten Menü vor und drücken Sie GO. HTOS™ hilft Ihnen die richtigen Messungen durchzuführen. Das Display zeigt OK oder NOT OK, ein Hilfemenü unterstützt Sie während der gesamten Zeit.
EASYTEST Installationstester mit Auto-Sequenz Funktion

EASYTEST Installationstester mit Auto-Sequenz Funktion

AUTO-Sequenz (Ra → RCD → Riso) Niederohmmessung mit >200 mA DC Isolationsmessung (L-PE / L-N / N-PE) Polarisationsmessung (PI & DAR) RCD Typ A, AC Netz- und Schleifenimpedanz Kurzschlussstrom mit OK / NO Anzeige Drehfeld Spannungsfall Interner Speicher und USB Anschluss Sicherheit nach CAT IV 300 V Die 3 neuen Modelle aus der COMBI Serie sind innovative und vielseitig einsetzbare Installationstester mit den grundlegenden Funktionen zur Prüfung elektrischer Anlagen und Installationen als auch E-Ladestationen. Stecker rein und einfach messen ⇒ Die neue Autosequenzmessung Ra → RCD → Riso macht´s möglich. Die Isolationsmessung gegen alle 3 Leiter (L-N-PE) und der große Speicher für 999 Messungen mit Speicherung auf 3 Ebenen + Textkommentar sind nur einige der vielen Highlights der neuen Modellreihe. Eine vom Benutzer abrufbares Hilfemenue für alle Messfunktionen bietet eine wertvolle Unterstützung beim Anschluss des Gerätes an die zu prüfende Anlage.
T 1000 PLUS Secondary injection relay test set

T 1000 PLUS Secondary injection relay test set

Multi-tasking test set designed for testing relays and transducers Max current output: 250 A Max AC voltage output: 250 V Max DC voltage output: 300 V Frequency generator: 15 ÷ 550 Hz Phase angle shifter Battery simulator 20 ÷ 260 V DC Oscilloscope function for current and voltage USB port – Microprocessor controller Test results and settings saved into local memory TD 1000 Plus model with two current outputs and high power at 15 Hz. T1000 PLUS is a protective relay test set especially designed to give the commissioning engineers a multitasking and highly reliable testing equipment. Tests performed Distribution relays Smart grid relays Single phase relays High burden relays
T 3000 Primary current injection test set

T 3000 Primary current injection test set

T 3000 is a primary current injection testing system designed to perform primary tests requested in substations commissioning. It allows to perform different tests and measurements on current transformers, voltage transformers, power transformers, protection relays, energy meters and transducers Main features Multi function primary test system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities 3000 V AC high-pot test Generates up to 800 A (option up to 4000A with high current booster) Microhmmeter function (option): up to 400A DC RS232 interface for pc connection Possibility to store test results in T 3000 local memory (up to 500 results) Compact and lightweight. Tests performed CT ratio CT ratio voltage mode CT polarity CT burden secondary side CT excitation curve CT knee voltage CT winding resistance Burden resistance VT ratio VT polarity VT burden secondary side PT ratio PT winding resistance Distribution relays Smart grid relays Single phase relays High burden relays CB operation time
Spannungsprüfer DUSPOL® expert

Spannungsprüfer DUSPOL® expert

Die langjährige Erfahrung in der Entwicklung zweipoliger Spannungsprüfer und die hohe Qualität zeichnet BENNING aus. DUSPOL® ermöglicht den Einsatz in modernen Anwendungsbereichen und erfüllt die hohen Sicherheitsstandards in Industrie und Handwerk. VDE-geprüft und zugelassen nach DIN EN 61243-3, VDE 0682-401:2015 Sichere Spannungsprüfung bis 1000 V AC/DC, ab 50 V auch bei leeren Batterien Messkategorie CAT IV 600 V, CAT III 1000 V Akustische/ optische Durchgangsprüfung LED Messstellenbeleuchtung Berührungsloser Kabelbruchdetektor Funktionen des DUSPOL® analog Lieferumfang inkl. Batterien Drehfeldprüfung (links/rechts) einpolige Prüfung des Außenleiters (Phase): Symbol „⚡” (rote LED) Messstellenbeleuchtung akustische und optische Durchgangsprüfung Frequenzmessung 1 – 1.000 Hz Spannungsanzeige 1 – 1.000 V AC TRUE RMS / 1.200 V DC Widerstandsmessung und Diodenprüfung mit Anzeige der Durchlassspannung beleuchtetes LC-Display Sensor berührungsloser Kabelbruchdetektor Lastzuschaltung über großflächige Drucktaster Vibrationsalarm im Prüfgriff schlagfestes, staub- und strahlwassergeschütztes Gehäuse (Schutzart IP 65) mit gummierten Prüfgriffen DIN EN 61243-3 – (VDE 0682-401) – Ausgabe: 2015 Geprüft und zugelassen gemäß international gültiger Norm IEC/EN 61243-3 (DIN VDE 0682-401), CAT IV 600 V bzw. CAT III 1000 V sichere Spannungsprüfung bis 1.000 V AC/DC Vibrationsalarm zur sicheren Spannungserkennung hochohmige Spannungsprüfung ohne Drucktasterbetätigung zuschaltbarer Lastkreis, Fehlmessungen durch kapazitive und induktive Blindspannungen werden durch bewusste Lastzuschaltung über Drucktaster ausgeschlossen bewusste Auslösung eines 30 mA FI-Schutzschalters batterieunabhängige Spannungsanzeige ab 50 V AC/DC akustische Durchgangsprüfung über Summer und gelbe LED (DUSPOL® expert, DUSPOL® digital) Drehfeldrichtungsprüfung im Drehstromnetz einpolige Außenleiterprüfung (Phase) Messstellenbeleuchtung über weiße High Power LED (DUSPOL® expert, DUSPOL® digital) Detektor zur berührungslosen Lokalisierung von Kabelbrüchen an offen liegenden und unter Spannung stehenden Leitungen (DUSPOL® expert, DUSPOL® digital) schlagfestes, staubdichtes und strahlwassergeschütztes Gehäuse (Schutzart IP 65) mit gummierten Prüfgriffen automatisch über Lichtsensor aktivierte LC-Display-Beleuchtung (DUSPOL® digital)
PRÜFBALL SPB ANALOG – Robuster analoger Spannungsprüfer mit Gummigehäuse

PRÜFBALL SPB ANALOG – Robuster analoger Spannungsprüfer mit Gummigehäuse

Sein einzigartiges Gehäuse aus Gummi kapselt das Messwerk ballartig ein und schützt optimal gegen harte Stöße, Wasser, Staub und elektrischen Schlag. Das macht den Spannungsprüfer unverwüstlich, sicher und langlebig. Der Prüfball SPB ist ein gummigekapselter Spannungsprüfer für den sicheren Einsatz in der Energieversorgung – genau, robust und wartungsfrei. Spannungsprüfer: präzise Anzeige der Spannung 20 – 500 V AC/DC / 50 V – 1000 V AC/DC extrem Spannungsfest – CAT IV 1000 V – VDE zertifiziert eindeutige LED-Anzeige für gefährliche Spannung Lastzuschaltung für Störspannungen und RCD-Auslösung vollständige Spannungsanzeige ohne Batterie – wartungsfrei präzises, störsicheres Drehspul-Messwerk mit direkter Anzeige Durchgangsprüfer: schneller Durchgangstest Phasen- und Drehfeldrichtungsprüfer: Phasenprüfer mit roter LED Anzeige Drehfeldprüfer mit LED Anzeige rechts / links Controller-überwachte Prüfung mit Fehlererkennung zur Vermeidung von Falschaussagen Phasen- und Drehfeldrichtungsprüfer können mit Handschuhen genutzt werden weitere Funktionen: Sicherheitsgehäuse aus Vollgummi extrem stoßfest Prüfelektroden mit Gewinde zum Aufschrauben von Zubehör leichte Bedienung Isolierungsfehler Erkennung durch zweifarbige Leitungsisolierung extrem stabiles Gehäuse, auch bei Kälte IP 65 – wasserdicht
Bump Tester und Gas Kalibrator

Bump Tester und Gas Kalibrator

Gesetzliche Vorschriften und die Notwendigkeit des täglichen Stoßprüfens erzeugen ein starkes Bedürfnis von Gastests. Gasdetektoren spielen eine wichtige Rolle für die Sicherheit von Menschen und Anlagen. Calibration Gas Description Ni-Br regulator Stainless steel regulator Non-reactive gases Suitable Suitable H2S Suitable Suitable SO2 Suitable Suitable NO Not recommended Suitable NO2 Not recommended Suitable Cl2 Not suitable Suitable NH3 Not suitable Suitable HCL Not suitable Suitable PH3 Not suitable Suitable SiH4 Not suitable Suitable HCN Not suitable Suitable
Stoil Cell For dielectric oil test

Stoil Cell For dielectric oil test

Oil cell for the HV test of dielectric oil The option allows the testing of the insulation characteristics of the oil by checking if there is no contamination. Main features Maximum test voltage: 12 kV Cell volume: about 1l Capacitance of the empty cell: 60 pF. Tests performed Tangent Delta
Neptune – Installationstester 1kV, CAT IV 600V mit Multimeterfunktion & Niederohmmessung

Neptune – Installationstester 1kV, CAT IV 600V mit Multimeterfunktion & Niederohmmessung

NEPTUNE ist ein Technologiemix aus einem Instrument für elektrische Sicherheitsprüfungen (Isolierung bis 1000 V und Niederohmmessung mit 200 mA), einem für Oberschwingungen und einem TRMS-Multimeter. Multifunktions-Multimeter zum Überprüfen von elektrischen Installationen Isolationsmessung mit 50, 100, 250, 500, 1000VDC. (VDE 0413 Teil 2) Niederohmmessung mit >200mA. (VDE 0413 Teil 4) Drehfeldrichtungsmessung durch einfaches Berühren der Leiter. (VDE 0413 Teil 7) Spannungsmessung mit geringer Eingangsimpendanz (LoZ). Widerstand und Durchgangsprüfung mit Summer. Spannung: DC, AC TRMS, AC+DC TRMS bis 1000V. Frequenz von Spannung und/oder Strom. MAX/MIN/PEAK/HOLD Funktionen. Präzise Anzeige mit 10.000 Punkten. Autorange Messungen mit automatischer AC/DC Erkennung. Ermittlung des Polarisationsindex (PI) & Dielektrischen Absorptionsverhältnis (DAR). DC, AC TRMS, AC+DC TRMS Strom bis 3000A mit Hilfe eines externen Wandlers. Leckstrom mit optionalem Stromwandler (HT96U). Einschaltströme von Elektromotoren (Dynamic InRush Current) Oberwellen von Strom- und Spannung & THD (%) Gesamtverzerrung
C.A 757 Spannungsprüfer

C.A 757 Spannungsprüfer

Automatische AC- und DC-Erkennung Automatische Erkennung von Widerständen, Dioden und Kapazitäten Automatische Bereichswahl Anzeige von gefährlich hohen Spannungen Abnehmbare Prüfspitzen Der C.A 757 ist ein kompaktes Prüf- und Messgerät, das einem Elektriker sämtliche alltäglich notwendigen Funktionen bietet. Der C.A 757 ist ein leichtes, gut in der Hand liegendes und bedienungsfreundliches Gerät in Schutzart IP54. Es ist gegen Staub und Fallhöhen bis zu 2 m geschützt. Auf seiner beleuchteten 3000 Digit-Anzeige sind die Messwerte direkt ablesbar. Die praktischen Prüfspitzen sind abnehmbar und leicht zu ersetzen, und sie lassen sich mit ihren Kabeln bequem in eine Aufnahme am Gehäuse einclipsen. Der C.A 757 ist leicht zu bedienen und wird schnell zum unverzichtbaren Helfer bei allen Prüf- und Wartungsarbeiten, bei optimalem Schutz für den Bediener: – geschützt gegen Spannungsspitzen bis 6 kV – geschützt bis 1000 V in allen Messarten – Anzeige von gefährlich hohen Spannungen – automatische Abschaltung nach 10 Minuten Nichtbenutzung Mit seiner doppelten Isolation und 600V CAT III entspricht der C.A 757 der neuen Multimeter-Norm IEC 61010-2-033. Der C.A 757 erkennt automatisch AC- und DC-Spannungen, ebenso wie Widerstände, Durchgänge, Dioden und Kapazitäten und er verfügt über eine kontaktlose Spannungserkennung. Jeder C.A 757 wird mit einem flexiblen MiniFlex®-Stromwandler ausgeliefert mit dem Ströme bis zu 300 A selbst an schwer zugänglichen Stellen gemessen werden können. Wichtigste Eigenschaften: • DC-Spannungsmessung: 3 mVDC bis 1000 VDC • AC-Spannungsmessung: 100 mVAC bis 1000 VAC • Strommessung: 500 mA bis 300 A (mit dem mitgelieferten MiniFlex®-Stromwandler) • Widerstandsmessung: 0,3 Ω bis 30 MΩ • Akustische Durchgangsprüfung für R ≤ 30 Ω • Kapazitätsmessung: 400 pF bis 30 mF • Diodentest • Kontaktlose Spannungserkennung • Messkategorie 600 V CAT III
eKAM Electronic primary injection test set

eKAM Electronic primary injection test set

eKAM is the new fully automatic electronic primary injection test equipment. e KAM test system includes two portable units: one control unit with a large graphical display, that adjusts the output, and one current unit (up to 2000, 3000, 5000A). It can also perform Step and Touch tests and ground resistance tests. Main features Fully automatic Two portable units: control and current units High current output: up to 2000 A, 3000 A and 5000 A Variable output frequency: 15 – 500 Hz CT ratio, burden and polarity test Large graphic display Advanced Test & Data Management Software for test set control, results storage and analysis Step & touch plus ground resistance tests with STLG option Reduced timing test USB interface and Ethernet interface for PC connection IEC 61850-9-2 sample values protocol interface Compact and lightweight Tests performed High current 2000, 3000, 5000, 7000 A CT ratio; CT polarity CT burden secondary side CT IEC 61850-9 CB operation time Earth impedance Line impedance Step & touch voltage
HTM - Hydrantentester

HTM - Hydrantentester

inkl. Standfüße, Batterie, Handbuch, Kalibrierzertifikat Nennweiten DN80 und DN100 • Durchflussmessbereich: 100-1500 l/min. bzw. 200 – 2500 l/min • Druck-Messbereich: 0-16 bar (0-10 bar; 0-6 bar) Anzeige am Manometer oder Datenlogger • Alu-Tragegriffe und Standfüsse mit Gummipuffer • Einlauf / Auslauf Beruhigungsstrecken 500 mm lang inkl. Standfüsse für einfachen Auf-/Abbau des Hydrantentesters • Digitalanzeige vor Ort für Durchfluss in l/min; bar; m³/h; m³ • Batteriebetrieb • Integrierter Datenlogger mit Impulsausgang bzw. 4-20 mA Ausgang für ext. Aufzeichnungsgerät / Datenlogger • Manometer; Digitalmanometer oder Drucksensoren mit 4-20 mA für ext. Aufzeichnungsgerät / Datenlogger
Ähnliche Suchen