100ADM MK5 Secondary Current Injection Test Set

100ADM MK5 Secondary Current Injection Test Set

0-100A output current True RMS metering with single cycle capture Auxiliary DC and AC output Multi-function auto-ranging timing system Current limit mode for fine control Automatic mains voltage selection Thermal and over-current protection The 100ADM mk5 Secondary Current Injection Test Set provides commissioning and maintenance engineers with a flexible system for testing protective systems. It has an easy to understand panel layout and a simple user interface. The status of every function can be seen at a glance, and there are no complex menus to navigate. The 100ADM mk5 keeps the familiar user interface of previous models but adds a new metering system that accurately measures the RMS of a single cycle. It also features a new current limit mode to provide very fine control of very low currents, even into low impedance loads. Current limit mode also assists in testing self-powered overcurrent protection as fitted to many 11kV ring main units. The unit has a range of outputs allowing injection of currents as low as a few mA and as high as 100A. Voltages up to 240V are available on the main outputs, allowing high impedance current relays and voltage relays to be tested. Four true RMS metering ranges are provided, allowing the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used on all inputs and outputs for convenience, reliability and safety. The 100ADM Mk5 Secondary Current Injection Test Set is comprehensively protected by overcurrent, duty cycle and thermal trips, and keeps the user fully informed of any trip condition. A stabilised DC supply is provided to power the relay under test, along with an independently switched and isolated 110V AC output. The back-lit display on the 100ADM mk5 is bright and clear with a wide viewing angle. The results of a test can be seen here as they appear on the display A very flexible two channel timing system is provided, allowing trip times, reset times and re-close times to be quickly measured to a high degree of accuracy. The timer auto-ranges to measure from 1ms to 99999.9s. The 100ADM can be used to test many types of single phase secondary protection including: 27/59 Over and under voltage relays 37 Under current 51 IDMT relays 50/76 Instantaneous overcurrent 59G Neutral voltage displacement 79 Auto-reclosers 2 Time delay relays 51G/50G Earth fault relays 67 Directional overcurrent (basic tests) 52 Miniature circuit breakers Tripping relays Thermal relays 90V Voltage regulating relays WEIGHT 23.9 kg DIMENSIONS 560 × 456 × 265 mm SUPPLIED ACCESSORIES Operating manual Mains lead Output lead set Spare fuses Carry strap OPTIONAL ACCESSORIES 100ADM-F, Part no. 006
PCU1-SP MK2 Primary Current Injection Test Set

PCU1-SP MK2 Primary Current Injection Test Set

5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switching 200A, 2000A and 5000A loading units Three range outputs on loading units Rugged, compact design Optional trolley mounting of system Secondary injection up to 100A Auxiliary metering input Direct reading CT ratio and polarity The PCU1-SP mk2 is a medium powered primary current injection set offering output currents up to 5000A (11.5kVA for 40seconds). The system consists of a separate control unit containing all metering and control functions and a loading unit, such as the NLU200, NLU2000 or the NLU5000, that provides the high current output. The PCU1-SP mk2 are ideally suited to primary current injection, stability testing and circuit breaker testing. In addition, the SP version offers direct-reading CT ratio and polarity tests and a 100A secondary injection output. Two loading units are available, delivering a maximum output current of 2000A or 5000A. Each loading unit has three output taps to allow for a wide range of load impedances. For example, the NLU5000 may be configured to either give a maximum current of 5000A on the 2.3V range, 2500A on the 4.6V range or 1250A on the 9.2V range. *The above is an image of the PCU1-SP and Loading Unit The control unit is rated at 11.5kVA with a 2 second overload capability of 23kVA using pulse mode. All metering is digital and a memory facility is provided to hold the current reading when the output trips or is switched off. The current is switched by a solid state device and is automatically switched off when the device under test trips. The PCU1-SP systems have a high accuracy timing system, allowing timing tests to be carried out to a resolution of 1ms. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available to test under and over current devices, re-closers, under and over voltage devices, current trips and circuit breakers. A full range of high current output leads are available to complement the system in a range of lengths. WEIGHT 26 kg DIMENSIONS 450 × 275 × 305 mm SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse set OPTIONAL ACCESSORIES Trolley mounting system, Part no A204-0005 100ADM-F, Part no. 006 100AL MK2 / MK3 Lead Set, Part no. A199-0003
HV TROLLEY2 High Voltage AC Test System

HV TROLLEY2 High Voltage AC Test System

20kVA output capability 0-3kV to 0-15kV options available Accurate digital metering Key operated supply switch Dual overload protection Variable electronic trip 10-110% of rated output Voltage and current metering Optional 5s – 5min test timer External 24V interlock and zero-volt interlock Emergency stop switch The HV trolley2 series of units are high power AC flash test sets with a 20kVA output capability. Single Trolley Version The maximum output voltage can be customised to be any voltage up to 15kV. The unit is housed in a rugged aluminium enclosure with a cover to protect the control panel. It is mounted on wheels to allow easy movement within a production environment. The HV trolley2 is provided with accurate digital voltage and current metering and a variable electronic trip. An external interlock input is also fitted to the unit. Outputs are provided to drive 24V warning beacons. The HV output is connected to the test object by a high voltage cable 5m long.
T 1000 PLUS Secondary injection relay test set

T 1000 PLUS Secondary injection relay test set

Multi-tasking test set designed for testing relays and transducers Max current output: 250 A Max AC voltage output: 250 V Max DC voltage output: 300 V Frequency generator: 15 ÷ 550 Hz Phase angle shifter Battery simulator 20 ÷ 260 V DC Oscilloscope function for current and voltage USB port – Microprocessor controller Test results and settings saved into local memory TD 1000 Plus model with two current outputs and high power at 15 Hz. T1000 PLUS is a protective relay test set especially designed to give the commissioning engineers a multitasking and highly reliable testing equipment. Tests performed Distribution relays Smart grid relays Single phase relays High burden relays
Stoil Cell For dielectric oil test

Stoil Cell For dielectric oil test

Oil cell for the HV test of dielectric oil The option allows the testing of the insulation characteristics of the oil by checking if there is no contamination. Main features Maximum test voltage: 12 kV Cell volume: about 1l Capacitance of the empty cell: 60 pF. Tests performed Tangent Delta
CU-Ps Primary Current Injection Test Set

CU-Ps Primary Current Injection Test Set

5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switching 200A, 2000A and 5000A loading units Three range outputs on loading units Rugged, compact design Optional trolley mounting of system Secondary injection up to 100A Auxiliary metering input Direct reading CT ratio and polarity The CU-Ps primary current injection test set is ideally suited to commissioning and maintenance testing where very high currents are required. The system consists of separate control and loading units for maximum flexibility. The control unit contains all control and metering circuitry, and is linked to the loading unit by control and metering cables. The control unit may be used with one of two loading units providing between 5000A or 6000A for 5 minutes or up to 10 or 12kA for short periods. Each loading unit has two outputs which may be connected in series or parallel for maximum flexibility. For example, the PLU-6k may be configured to either give a maximum current of 3000A at 6.6V or 6000A at 3.3V. The control and loading units are each housed in tough steel cases fitted with castors and protective lifting handles. The loading units have a small plan area to allow them to be positioned as close as possible to the test object, minimising power requirements and maximising the available current. The CU-Ps control unit is shown here with a PLU-6k loading unit. This combination may be used to inject currents of up to 6000A for 5 minutes or 12000A for 1 second. The CU-Ps primary current injection test set is ideally suited to all primary current injection tasks, including testing under and over current relays, circuit breakers and CT ratio testing. The control unit is rated at 20kVA and has digital metering. A memory facility is provided on the metering to hold the current reading when the output trips or is switched off. The current is automatically switched off when the device under test trips. The CU-Ps systems have a high accuracy timing system with 1ms resolution. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available for under and over current devices, reclosers, under and over voltage devices, current trips and circuit breakers. The AC output current is metered by a true RMS memory ammeter (acquisition time 20ms) with a liquid crystal display. The current metering has 3 ranges corresponding to 10%, 50% and 100% of the maximum rating of the loading unit. In addition, a 200% metering range is enabled in pulse mode for the 0.2s, 0.5s and 1s settings only. The CU-Ps systems have a flexible timing system with two contact inputs and 5 operating modes. Each contact circuit automatically selects for N/O or N/C contacts, and the status of each contact input is shown by an LED. The timing channels may also be triggered by a dc voltage between 24 and 240V. *Pulse mode applies current to the load for a maximum of the specified time. If contact set 1 changes state or the current drops below 20% of the metering range during the pulse time, the timer is stopped. The maximum output current is increased in pulse mode. The maximum obtainable current is set by the impedance of the test object and output leads. **Current operated mode is used to time circuit breakers with no auxiliary contacts. The timer is started when the current exceeds 20% of the selected metering range (e.g. 1000A on the PLU-5k 5000A range). The timer stops when the current falls. All test results from the CU-Ps can be stored in a USB memory key. The unit has a real-time clock to time and date-stamp all results. To log the results, first enter a comment for your results using the optional keyboard, and then select AUTO STORE. Whenever the timer stops, the time, current and all other parameters are added to a spreadsheet file on the USB key. You can then view the current set of results on the display or take the USB key out and open the file on your PC. All results are stored in a folder on the USB key named with the test date in a file named with the time. The CU-Ps primary current injection test sets and loading units are CE marked and are designed to meet the requirements of BS EN61010. The system is protected by electronic trips on the outputs, circuit breaker and fuse on the mains input, and a circuit breaker on the control unit output. The unit also has a duty cycle trip on the loading unit output and thermal protection. WEIGHT 115 kg DIMENSIONS 660 × 400 × 740 mm OPTIONAL ACCESSORIES A range of output lead sets are available to complement the CU-Ps system with current ratings between 3000A and 6000A. The leads are double insulated and have good flexibility. SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse set
Bump Tester und Gas Kalibrator

Bump Tester und Gas Kalibrator

Gesetzliche Vorschriften und die Notwendigkeit des täglichen Stoßprüfens erzeugen ein starkes Bedürfnis von Gastests. Gasdetektoren spielen eine wichtige Rolle für die Sicherheit von Menschen und Anlagen. Calibration Gas Description Ni-Br regulator Stainless steel regulator Non-reactive gases Suitable Suitable H2S Suitable Suitable SO2 Suitable Suitable NO Not recommended Suitable NO2 Not recommended Suitable Cl2 Not suitable Suitable NH3 Not suitable Suitable HCL Not suitable Suitable PH3 Not suitable Suitable SiH4 Not suitable Suitable HCN Not suitable Suitable
Elektro-Rütteltisch

Elektro-Rütteltisch

Elektro-Rütteltisch zur Normgerechten Herstellung von Betonprobekörper
DRTS 6 Automatic relay test set

DRTS 6 Automatic relay test set

Main features Multi-tasking relay test equipment designed for testing protection relays, energy meters, transducers Output: 6×15 A (80 VA); 4×300 V (85 VA); 1×260 V DC High accuracy outputs: 0.1 %; 0.05% (HP) Analog measurement inputs IEC 61850 protocol interface USB and RS232 port Controlled by PC laptop or local control by PDA Tests performed Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays Low power relays DC relays Energy meters Transducers Power quality meters
DRTS 3 PLUS Automatic relay test set

DRTS 3 PLUS Automatic relay test set

DRTS 3 PLUS power system simulator is designed to give the highest accuracy when testing and calibrating protective relays, energy meter, transducer and power quality devices. This diagnostic and calibration equipment is the perfect solution to perform automatic testing on protection devices. Main features Multi-tasking relay test equipment designed for testing protection relays, energy meters, transducers Output: 3×15 A (100 VA); 4×300 V (85 VA); 1×260 V DC High accuracy: better than 0,05% Analog measurement inputs IEC 61850 communication Protocol interface USB and RS232 port Controlled by PC laptop or local control by PDA Lightweight Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays Low power relays DC relays Energy meters Transducers Power quality meters
DRTS 66 – Automatic relay test set

DRTS 66 – Automatic relay test set

DRTS 66 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 6 Current and 6 Voltage generators simultaneously available. Main features Manual control of the display 6 Current and 6 Voltage generetors plus 1 battery simulator outputs Current outputs : 6 x 32 A, 3 x 64 A, 1 x 128 A Power outputs: 6 x 430 VA, 3 x 860 VA, 1 x 1000 VA Voltage outputs: 6 x 300 V at 100 VA High accuracy outputs: better than 0.05% IEC 61850 protocol interface USB and ethernet interface Advanced testing and data management software TDMS Complete library of relays from the major manufacturers Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays High burden relays Low power relays DC relays Energy meters Transducers Power quality meters
DRTS 66 – Automatic relay test set

DRTS 66 – Automatic relay test set

DRTS 66 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 6 Current and 6 Voltage generators simultaneously available. Main features Manual control of the display 6 Current and 6 Voltage generetors plus 1 battery simulator outputs Current outputs : 6 x 32 A, 3 x 64 A, 1 x 128 A Power outputs: 6 x 430 VA, 3 x 860 VA, 1 x 1000 VA Voltage outputs: 6 x 300 V at 100 VA High accuracy outputs: better than 0.05% IEC 61850 protocol interface USB and ethernet interface Advanced testing and data management software TDMS Complete library of relays from the major manufacturers Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays High burden relays Low power relays DC relays Energy meters Transducers Power quality meters
ALPHA 2-500

ALPHA 2-500

Druckprüfmaschine ALPHA 2-500 zur Druckfestigkeitsprüfung an Bohrkernen, Zylinder nach EN 12504-1
ALPHA 4-3000

ALPHA 4-3000

Druckprüfmaschine ALPHA 4-3000 zur Druckfestigkeitsprüfung an ganzen Mauersteinen gemäß EN 771 wie z.B. Ziegel, Kalksandstein, Porenbeton, Bimsstein, Naturstein
T 3000 Primary current injection test set

T 3000 Primary current injection test set

T 3000 is a primary current injection testing system designed to perform primary tests requested in substations commissioning. It allows to perform different tests and measurements on current transformers, voltage transformers, power transformers, protection relays, energy meters and transducers Main features Multi function primary test system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities 3000 V AC high-pot test Generates up to 800 A (option up to 4000A with high current booster) Microhmmeter function (option): up to 400A DC RS232 interface for pc connection Possibility to store test results in T 3000 local memory (up to 500 results) Compact and lightweight. Tests performed CT ratio CT ratio voltage mode CT polarity CT burden secondary side CT excitation curve CT knee voltage CT winding resistance Burden resistance VT ratio VT polarity VT burden secondary side PT ratio PT winding resistance Distribution relays Smart grid relays Single phase relays High burden relays CB operation time
Haftzugprüfgerät ConsurTest

Haftzugprüfgerät ConsurTest

Haftzugprüfgerät zur Ermittlung der Oberflächenzugfestigkeit, Haftzugfestigkeit bzw. Abreißfestigkeit an Beton, Estrichen, Mörtel, Putz, Wärmeverbundsystemen (WDVS), Parkett, Asphalt und vielen mehr.
MultiTest HT700 – ARC DGUV Vorschrift 3 Tester mit Touchscreen

MultiTest HT700 – ARC DGUV Vorschrift 3 Tester mit Touchscreen

DGUV V3 Gerätetester zur Prüfung elektrischer Betriebsmittel inkl Schweißgeräte Prüfung im Rahmen der DGUV V3, BetrSichV gemäß: • DIN VDE 0701-02:2008 (EN 62638) Prüfung elektrischer Geräte/Arbeitsmittel • DIN VDE 0751-1:2015 (EN 62353): Prüfung medizinisch elektrischer Geräte, wie Pflegebetten etc. • DIN VDE 0544-4 (EN 60974-4): Prüfung elektrischer Schweißgeräte Leistungsmerkmale: • Prüfung von mobilen Personenschutzschaltern PRCD (2-/3-polig) Typ S, S+, K • Prüfung von Fehlerstromschutzeinrichtungen RCD Typ AC, A, F, B, B+ • Schnittstellen: WLAN, RJ45 (LAN), USB, SD-Kartenslot und Bluetooth® • Standard, erweiterte und kundenspezifische Sichtprüfungen • Prüfung von Lichtbogenschweißeinrichtungen • Gerätetester kann in IT-Netzen betrieben werden • Datenbankverwaltung von Kunden & Betriebsmitteln mit ID-Nr. • Erstellung und Zuweisung individueller Prüfabläufe und -intervalle • Automatischer und manueller Prüfablauf einstellbar • Geringe Betriebskosten, kostenfreie Updates über WLAN, LAN, USB • Touch-Screen für Gesten, Softkey-Tastatur (QWERTZ), grafische Bedienfelder, „On-/Off-Slider“ zum Aktivieren/Deaktivieren von Funktionen • Unbegrenzte Datenspeicherung über SD-Karte • Messergebnis mit eindeutiger GUT / SCHLECHT Anzeige • Komplett – ein Gerätetester für alle VDE Geräteprüfungen
HT Instruments JUPITER,  VDE0100 Tester & Multimeter TRMS

HT Instruments JUPITER, VDE0100 Tester & Multimeter TRMS

VDE0100 Tester - CAT IV 600V mit TRMS Multimeterfunktion Das erste Multimeter mit Funktionen, die nur in Standard-Sicherheitstestern und professionellen High-End-Multimetern verfügbar sind. •Jupiter ist das einzige Multimeter, das auch die Sicherheit der elektrischen Installation überprüfen kann. •Es vergleicht die Messung mit den vorgegebenen Grenzwerten und zeigt ein klares OK / NOT OK an. •Die Funktionen von Jupiter sind für gewöhnlich nur in high-end Messgeräten integriert. •An mir können unterschiedliche externe Stromwandler zur Messung von AC TRMS, DC, AC+DC, und Einschaltströmen angeschlossen werden. •Ich bin handlich, sehr robust und kompakt •Autorange Messungen mit automatischer AC/DC Erkennung •DC,AC TRMS, AC+DC TRMS bis 690V •LoZ Spannungsmessung mit geringer Eingangsimpedanz •DC, AC TRMS, AC+DC TRMS Strom mit Hilfe eines externen Wandlers •Frequenz von Spannung und/oder Strom •Widerstands- und Durchgangsprüfung mit Summer •MIN/MAX/PEAK/HOLD Funktionen •Anzeige mit 6000 Punkten
I-Test eine vollautomatische Lösung für das Testen und Verifizieren von Gas-Pro und T4

I-Test eine vollautomatische Lösung für das Testen und Verifizieren von Gas-Pro und T4

I-Test ist eine vollautomatische Lösung für das Testen und Verifizieren von Gas-Pro und T4, sodass diese in funktionsfähigem Zustand ihre Arbeit verrichten. Specifications Size 110 x 250 x 320mm (4.3 x 9.8 x 12.6 ins) Weight 2kg (70.5oz) Alarms 9-12V @ 3A I-Test backup battery 200 speedy bump tests with 15 second intervals bewteen tests 5 hours in standby with no bump test Battery life approximately 500 cycles Charge time 7 hours RTC backup battery 3 year life USB interface One standard USB type A socket for USB Flash Memory stick One standard USB type B socket for connections to PC Inlets/Outlets Single gas inlet (requires demand flow regulator) Purge inlet (air) Exhaust Regulators Demand flow regulator required Storage capacity Internal 2GB MicroSD card Temperature specifications Operating temperature: -10°C to +50°C Storage temperature: -25°C to +60°C Charging temperature: 0°C to +40°C Humidity 0% and 95% relative humidity (non-condensing) at +40°C Ingress protection IP20
BP 400 S

BP 400 S

Prüfmaschine für die statische und dynamische Prüfungen von Gleis- und Weichenschwellen aus Beton nach EN 13230
Rautiefen-Messgerät SRC

Rautiefen-Messgerät SRC

Rautiefen-Messgerät SRC gemäß EN DIN EN ISO 13473-1 Laser-Messverfahren für die Messung und Berechnung der Rautiefen Rt nach ZTV-ING., DAfStb-Rili SIB an allen Flächen (Decke, Wand, Boden, Schrägen etc.)
Luftgehaltsprüfer die Frischbetonkontrolle

Luftgehaltsprüfer die Frischbetonkontrolle

Luftgehaltsprüfgerät zur schnellen Kontrolle des Luftporengehaltes im Frischbeton gemäß EN 12390-7
PSM 3 / 230

PSM 3 / 230

Probenschleifmaschine für Zylinder, Bohrkerne, Würfel oder Pflastersteine zur Probenvorbereitung gemäß den Anforderung der EN 12390-1
STS 3000 LIGHT Multifunction substation test set

STS 3000 LIGHT Multifunction substation test set

STS 3000 light is a testing system designed to perform Tan Delta and capacitance measurement on CTs, VTs, Power Transformer and Circuit Breaker Main features Fully automatic Variable output frequency: 15 – 500 Hz Output voltage up to 12 kV Power dissipation factor test with the module TD 5000 ( voltage up to 12 kV) PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report USB interface and Ethernet interface for PC connection Compact and lightweight. Tests performed Tangent Delta Capacitance
STS 3000 LIGHT Multifunction substation test set

STS 3000 LIGHT Multifunction substation test set

STS 3000 light is a testing system designed to perform Tan Delta and capacitance measurement on CTs, VTs, Power Transformer and Circuit Breaker Main features Fully automatic Variable output frequency: 15 – 500 Hz Output voltage up to 12 kV Power dissipation factor test with the module TD 5000 ( voltage up to 12 kV) PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report USB interface and Ethernet interface for PC connection Compact and lightweight. Tests performed Tangent Delta Capacitance
Labor- bzw. Analysensiebmaschinen für die Gesteinskontrolle

Labor- bzw. Analysensiebmaschinen für die Gesteinskontrolle

Labor- bzw. Analysensiebmaschine zur Bestimmung der Korngrößenverteilung nach EN 933-1 bzw. EN 933-2
20A DC booster Winding resistance test

20A DC booster Winding resistance test

Maximum output current: 20 A DC Maximum power on output sockets: 400 W Current output switch: controlled by STCS Current output amplitude: controlled by STS 5000 or STS 4000 The 20A DC STCS booster allows to perform resistance tests on a PT with a current up to 20 A DC. The option is used together with STS 5000 and STS 4000 and must be connected to STCS module.
Blätterkatalog - Prüfsysteme und Prüfmaschinen für die Materialprüfung - PM1000.01de

Blätterkatalog - Prüfsysteme und Prüfmaschinen für die Materialprüfung - PM1000.01de

Schauen Sie sich unseren Blätterkatalog an - einfach unsere Seite: https://www.formtest.de/PM1000.php aufrufen, oder unten auf Webseite besuchen klicken. Blätterkatalog / Produktübersicht Prüfgeräte und Maschinen für die Baustoffprüfung. Schauen Sie sich unseren Blätterkatalog an - einfach auf den Link klicken.
Continental__CrossContact-H-T__P

Continental__CrossContact-H-T__P

Natürlich! Hier ist eine Produktbeschreibung für den Continental CrossContact H/T Reifen auf Deutsch: Continental CrossContact H/T Reifen – Produktspezifikationen Modell: Continental CrossContact H/T Typ: Ganzjahres-SUV-Reifen Verfügbare Größen: Verschiedene Größen von 15 bis 20 Zoll Durchmesser Höhe/Breite: Variiert je nach Größe, typischerweise zwischen 55 und 75 für das Verhältnis sowie 225mm bis 275mm für die Breite Reifenaufbau: Radial Tragfähigkeitsindex: Variiert von 95 bis 115, je nach Größe Geschwindigkeitsindex: H (bis 210 km/h), T (bis 190 km/h) oder V (bis 240 km/h), je nach spezifischer Größe Profil: Symmetrisches Design für ausgewogene Leistung und Komfort Eigenschaften: Ganzjahresleistung: Ausgewogene Traktion auf trockenen, nassen und leichten winterlichen Straßenbedingungen Komfort: Geringer Rollwiderstand und ruhiger Lauf für ein komfortables Fahrerlebnis Haltbarkeit: Robuste Lauffläche mit hoher Widerstandsfähigkeit gegen Abrieb und gleichmäßiger Abnutzung Sicherheit: Gute Straßenhaftung und Bremsleistung für eine sichere Fahrt unter verschiedenen Bedingungen Ideal Für: SUVs und Crossover-Fahrzeuge, die ganzjährige Flexibilität und Komfort benötigen Fahrten auf unterschiedlichen Straßenbelägen und Witterungsbedingungen Hinweis: Überprüfen Sie vor dem Kauf die Kompatibilität der Größe und Spezifikationen mit Ihrem Fahrzeug.
Hochfrequenz-Rütteltisch

Hochfrequenz-Rütteltisch

zur Herstellung von Betonprobekörper