Finden Sie schnell testem für Ihr Unternehmen: 533 Ergebnisse

TPT9000 Transformer Polarity Tester

TPT9000 Transformer Polarity Tester

Fast polarity testing of both voltage and current transformers. Compact and light Easy to use, plug & play Smart detection of incorrect connection Proving unit included in the kit as standard Fused lead sets included for user safety Supplied in a protective case. Long battery life Built in battery monitor The TPT9000 Transformer Polarity Tester is used for determining the correct polarity of current and voltage transformers. This device is a smart plug and play instrument designed for Commissioning Engineers. A lightweight instrument it comes with magnetised back panel, making it for storage on metallic walls or panels. TPT9000 automatically detects if the transformer has been connected incorrectly. The device comes with a proving unit to check the correct operation of the unit in the field. A set of 600V CAT IV fused test leads terminated in shrouded 4mm connectors is also included with the unit, along with 4 F500mA HRC fuses. The instrument is designed to be used on ‘dead’ systems (i.e., no externally supplied voltages are present on the test object). We strongly advise you not to connect the TPT9000 to a live system. Always make sure that the power of the device under test is off. TPT9000 Transformer Polarity Tester is designed for use in industrial and electrical substation environments on altitude level of maximum 2000m above sea level. Operating temperature is between 0°C and 45°C, while storage temperature is -20°C to 60°C. TPT9000 requires a single PP3 9V battery to operate. Battery level is automatically monitored, and the device will not perform a test if the battery voltage is below a useable level. WEIGHT 0.6 kg DIMENSIONS 118 × 79 × 32 mm SUPPLIED ACCESSORIES Proving unit 1 off 1m Black fused lead 1 off 1m Red fused lead 1 off 1m Blue fused lead 1 off 1m Brown fused lead Operating & Maintenance Manual Unit carry set case 9V battery OPTIONAL ACCESSORIES/SPARES Proving Unit, Part No. 249-0001 Complete replacement output lead set, Part No. A249-0002 Carry Case, Part No. A249-0003
PSM 3 / 230

PSM 3 / 230

Probenschleifmaschine für Zylinder, Bohrkerne, Würfel oder Pflastersteine zur Probenvorbereitung gemäß den Anforderung der EN 12390-1
ExactSign™ COVID-19 Antigen Rapid Test Casette – Vorgefüllte Pufferlösung CE1434-Laientest Vorgefüllte Pufferlösung

ExactSign™ COVID-19 Antigen Rapid Test Casette – Vorgefüllte Pufferlösung CE1434-Laientest Vorgefüllte Pufferlösung

Der ExactSign™ COVID-19 Antigen Rapid Test (Nasenabstrich) mit Vorgefüllte Pufferlösung ist ein chromatographischer Schnellimmunoassay für den qualitativen Nachweis von COVID-19, CE1434 zertifiziert Mit der Änderung der Coronavirus-Testverordnung (TestV) vom 29.06.2022 ist die Erstattungsfähigkeit der Antigen-Schnelltests neu geregelt. Der Anspruch nach § 1 Absatz 1 Satz 1 in Bezug auf eine Diagnostik mittels PoC-Antigen-Tests (Point-of-Care-Antigen-Tests) beschränkt sich auf Antigen-Tests, die in der vom Gesundheitssicherheitsausschuss der Europäischen Union beschlossenen gemeinsamen Liste von Corona-Antigen-Schnelltests aufgenommen wurden (Common RAT List des HSC). Dieses Dokument baut auf der Empfehlung des Rates vom 21. Januar 20211 auf, in der die EU-Mitgliedstaaten einstimmig beschlossen, einen gemeinsamen Rahmen für die Verwendung und Validierung von Antigen-Schnelltests und die gegenseitige Anerkennung von COVID-19-Testergebnissen in der EU festzulegen. --------------------- Der ExactSign™ COVID-19 Antigen Rapid Test (Nasenabstrich) mit vorgefüllte Pufferlösung ist ein chromatographischer Schnellimmunoassay für den qualitativen Nachweis von COVID-19 / Nasenabstrich bei symptomatischen Personen und erkennt entsprechend der Bridging-Prüfung des Paul-Ehrlich-Institut die Omikron Variante Download. Die Identifizierung basiert auf den monoklonalen Antikörpern, die für das Nukleokapsid (N)-Protein von SARS-CoV-2 spezifisch sind. - BfArM gelistet AT1331/21 (erstattungsfähig) - Evaluiert durch das Paul-Ehrlich-Institut (PEI) - PEI Liste-(90%) Download - TÜV-SÜD zertifiziert - CE1434 zertifiziert - Ausgezeichnete Leistung im Vergleich zu molekularen Methoden - Klinische Sensitivität: 93,2% - Klinische Spezifität: 99,2% - Einfache Anwendung durch Abtupfen der Nasenvorderseite - Testergebnisse in nur 10 min. Nachweis mutierter Viren: - Variante Alpha B.1.1.7 September 2020 - Variante Beta B.1.351 Mai 2020 - Variante Gamma P.1 November 2020 - Variante Delta B.1.617.2 Oktober 2020 - Variante Omikron B.1.1.529 November 2021 Paul-Ehrlich-Instituts vergleichende Evaluierung der Sensitivität von SARS-CoV-2-Antigenschnelltests Download Diese vergleichende Evaluierung einer großen Anzahl von SARS-CoV-2 Antigenschnelltests (point of care tests; POCT) verschiedenen Designs und verschiedener Hersteller mit einem einheitlichen Probenset ermöglicht einen Überblick über den derzeitigen Stand der Technik hinsichtlich ihrer Sensitivität. ZERTIFIKATE | PRÜFBERICHTE: BfArM gelistet: Download Statement Mutationen (27.01.2022): Download Statement Mutationen (30.11.2021): Download Omicron Viarant Detect Results: Download DAkkS TÜV-SÜD: Download CE1434 Zertifikat: Download EC Declaration of Conformity: Download Gebrauchsanweisung: Download BfArM gelistet AT1331/21 (erstattungsfähig): ja Evaluiert durch das Paul-Ehrlich-Institut (PEI): ja PEI Liste (90%): ja TÜV-SÜD zertifiziert: ja CE1434 zertifiziert: ja Klinische Sensitivität: 93,2% Klinische Spezifität: 99,2% Testergebnisse in nur 10 min.: ja
Unser magnetisch angetriebener Hochfrequenzpulsator bis 550 kN für Materialprüfungen

Unser magnetisch angetriebener Hochfrequenzpulsator bis 550 kN für Materialprüfungen

Highlights Hohe Frequenzen Automatische Anrisserkennung Energieeffizient Kurze Prüfzeiten Anwendungen Für Werkstoffuntersuchungen Für Untersuchungen von Bauteilen mit geringem Spiel und Dämpfung Zug-Druck-Schwell-Versuche
Schuhlöffel mit Tester für Rauchmelder

Schuhlöffel mit Tester für Rauchmelder

Schuhlöffel mit Tester für Rauchmelder. Kunststoff Artikelnummer: 919087 Druckfarben: 1 Gewicht: 125 gram
Insulation Tester + True RMS Multimeter  CEM DT-9985

Insulation Tester + True RMS Multimeter CEM DT-9985

Insulation test 0,001MΩ to 4000MΩ; Test voltage 125V, 250V, 500V, 1000V; 40.000 Counts LCD backlit display; AC True RMS Multimeter; Up to 2,000 measurement values storage; CAT III 1000V, CAT IV 600V The Insulation Multimeter DT-9985 combines the funktions of Insulation meter with True RMS Multimeter into a compact and portable device that provides versatility for both fault detection and preventive maintenance. Features: 40.000 Counts LCD backlight display with bargraph Insulation test Voltage 125V, 250V, 500V, 1000V. Insulation test: 0,001MΩ to 4000MΩ True RMS Multimeter: DC Voltage, AC Voltage, DC Current, AC Current, Resistance, Capacitance, Frequency, Duty Cycle, Temperature measurement, Diode Test, Continuity Check Automatic discharge of capacitive circuits Min / Max function and Peak Hold Measurement rate at 2 times per second Up to 2000 measured values storage Automatic shutdown Safety: CAT III 1000V, CAT IV 600V IP67 Waterproof, 2 meter drop test
MetaScope 5 Schichtdickenmessgerät

MetaScope 5 Schichtdickenmessgerät

Coulometrische Schichtdickenmessung für galvanische Schichten aus Zinn, Nickel oder Silber Lang-erprobtes Schichtdickenmessgerät in der 5. Generation Coulometrische Schichtdickenmessung nach EN ISO 2177 Für Drahthersteller: fertigungsbegleitende Kontrolle von Zinn-, Nickel- oder Silberüberzügen auf Kupferdrähten bei Galvanik-Stationen Für kabelverarbeitende Industrien: Wareneingangskontrolle der spezifizierten Metallauflagen
Baugruppen für die Nachrichtentechnik

Baugruppen für die Nachrichtentechnik

Baugruppen für die Nachrichtentechnik, Electronics Manufacturing Services, Herstellung elektronischer HF-Flachbaugruppen sowie Moduleinheiten und kompletten Geräten. Gemäß IPC-JSTD001 Kl. 3
Sie sind auf der Suche nach professionellen Integritätstests für Membranfilter

Sie sind auf der Suche nach professionellen Integritätstests für Membranfilter

Willkommen bei der Flow Test GmbH. Mehr als 20 Jahre Kompetenz auf dem Gebiet der Integritätsprüfung von Membranfiltern! Seit dem Jahr 1998 ist die Flow Test GmbH erfolgreich auf dem Gebiet der Integritätsprüfung von Membranfiltern tätig. An unserem Stammsitz in Katlenburg-Lindau entwickeln und fertigen wir Filterintegritätstestgeräte, Heizbare-Filtergehäuse und Filter-Trockner, Wartung und Kalibrierung, Qualifizierungen IQ/OQ/PQ.
Mobile Klimaanlagen & Splitgeräte im Test

Mobile Klimaanlagen & Splitgeräte im Test

In der aktuellen Ausgabe von Juni 2020 (test 06/2020) vergleicht die Stiftung Warentest verschiedene Monoblock & Splitgeräte miteinander. Das Panasonicgerät erreichte eine Gesamtnote von 2,6. Schon 2018 (Ausgabe test 07/2018) war das Panasonic Etherea Raumklimagerät Testsieger im Vergleich der Stiftung Warentest. Im Vergleich der beiden Bauarten ist das Ergebnis des Tests klar: Monoblock Klimageräte sind alles in allem eine ziemlich ineffiziente Lösung. Eine geringe Kühlleistung kommt zusammen mit einem wenig effizientem Setup und einem hohen Stromverbrauch. Splitgeräte dagegen kühlen deutlich effektiver: Sie kühlen die Raumluft nicht nur deutlich schneller auf die gewünschte Temperatur herunter, sondern verbrauchen dabei auch deutlich weniger Strom. Die Wärme wird nicht einfach nach außen geblasen, sondern über das Kühlmittel nach außen abtransportiert, ohne dass warme Luft nachströmt. test 06/2020 Stiftung Warentest: „Fest installierte Klimaanlagen deklassieren mobile Modelle“
Produktentwicklung

Produktentwicklung

Flexibles Bohr-Fräszentrum zur Stahlträgerbearbeitung
TELENOT

TELENOT

Einbruchmeldeanlagen, Alarmanlagen, Brandmeldeanlagen, Übertragungstechnik, Zutrittskontrolle Erleben Sie die Zukunft der modernen Gefahren- und Einbruchmeldetechnik. Mit der neuen Generation an Einbruch- und Gefahrenmelderzentralen hiplex eröffnet TELENOT eine neue Zeitrechnung. Mit einer Entwicklungsleistung von bislang 50 Mannjahren in den Bereichen Hard- und Software sowie Testing und dem damit größten Entwicklungsprojekt in der Firmengeschichte der TELENOT ELECTRONIC GMBH wird erstmals eine Zentrale auf den Markt der elektronischen sicherheitstechnik gebracht, die hinsichtlich - Flexibilität in der Systemarchitektur - Vielfältigkeit und Performance in den Anwendungen und - innovativer, graphischer Benutzeroberfläche zur Systemparametrierung den Maßstab für geprüfte und nachhaltige Sicherheitslösungen für alle Gebäudeanforderungen setzt. hiplex ist die technische Plattform, um in der Gegenwart und Zukunft durch verschiedenste Evolutionsstufen auf alle Anforderungen des Marktes reagieren zu können. Durch die dezentrale Prozessorstruktur lassen sich Signale und Meldungen nahezu gleichzeitig bearbeiten. Der bewährte com2BUS ist wesentlich erweitert.
Zeiterfassungssystem

Zeiterfassungssystem

Die Arbeitszeit Ihrer Mitarbeiter kann entweder mit der Kommen & Gehen Buchung über Tablets als Stechuhr, dem Tasksymbol oder über unsere Weboberfläche erfasst werden. Mit der SaaS.de Zeiterfassung können Ihre Mitarbeiter ganz einfach Ihre Arbeitszeiten erfassen. Die Arbeitszeit Ihrer Mitarbeiter kann entweder mit der Kommen & Gehen Buchung über Tablets als Stechuhr, dem Tasksymbol oder über unsere Weboberfläche erfasst werden. Zusätzlich können Sie mit unserem System weltweit und mobil Zeiten mit Hilfe unserer Smartphone-App buchen. Auch im Nachhinein können bestehende Buchungen erstellt, geändert und gelöscht werden.
MT KÜHLWASSER CHECK / MT COOLING WATER CHECK

MT KÜHLWASSER CHECK / MT COOLING WATER CHECK

Maßgeschneiderter Testkoffer für 3 verschiedene Tests / Customized Test Kit for 3 Different Tests For the English version see below. Der Testkoffer MT KÜHLWASSER CHECK wurde speziell entworfen, um Ingenieuren und technischem Wartunspersonal ein effektives vor-OrtÜberwachungshilfsmittel zur Verfügung zu stellen, um regelmäßig den Zustand und die Qualität von Nitrit-additivierten Kühlwassersysteme von Dieselmotoren zu ermitteln. Im Testkoffer sind drei verschiedene Tests enthalten: ph-Wert-Bestimmung, Chloridund Nitrit-Test. Die regelmäßige Überprüfung jeweiliger Parameter ermöglicht eine schnelle und genaue Beurteilung des Korrosionschutzniveaus des für das Kühlwassersystem verwendeten Additivpaketes. Die richtige Konzentration der Korrossionsinhibitoren im Kühlwasser trägt zu einem optimalen Korrosionsschutz und optimalen Betriebsbedingungen des Motorsystems bei. Merkmale: Messbare Parameter • pH-Wert • Chloridgehalt • Nitrit Test Vorteile: • Schnelle und genaue vor-OrtBestimmung des Zustandes von Motorkühlsystem • Aufrechterhaltung des optimalen Korrosionsschutzniveaus des Additivpaketes • Möglichkeit rechtzeitiger Korekturmaßnahmen The test kit MT COOLING WATER CHECK has been specifically designed to provide engineers and technical maintenance personnel with effective on-site monitoring tool to regularly determine the condition and quality of the cooling water systems with nitrite additives in diesel engines. Three different tests are included in the test kit: determination of pH value, chlorides and nitrite tests. Regular verification of these particular parameters enables a quick and accurate assessment of the corrosion protection level of the additive package used for the cooling water system. Proper concentration of the corrosion inhibitors in the cooling water helps to maintain optimum corrosion protection and optimum operating conditions of the engine system. Features: Parameters to measure • pH Value • Chlorides • Nitrite Benefits: • Quick and accurate on-site determination of engine cooling water system condition • Maintenance of optimum corrosion protection level of the additive package • Possibility of corrective actions in due time • Compact design
TeleForm

TeleForm

TeleForm ist die Erfassungssoftware für Formulare und Dokumente. Belege aller Art können mit TeleForm automatisch und intelligent gelesen, analysiert und klassifiziert werden. Mit TeleForm können Sie mehr Daten in kürzerer Zeit und in besserer Qualität erfassen. Denn anstelle von manuellem Abtippen von Daten liest TeleForm Dokumente mittels eines Dokumentenscanners ein. TeleForm ist eine der weltweit führenden Capturing Plattformen: Design: Als einzige Capturing-Plattform verfügt TeleForm über ein Modul für WYSIWYG- Formulardesign und kann deswegen sowohl bestehende Formulare einlesen als auch neue beleglesegerechte Formulare erzeugen. Input und Output: Mit dem AutoMerge Publisher-Modul sind vorbefüllte Formulardrucke und Serienversendungen von Formularsätzen möglich. Erkennung - sogar per Fax: TeleForm verwendet weltweit führende Erkennungstechnologie für OCR, ICR-Handschrift, Logo-Erkennung, Lesung von Ankreuzfeldern. Diese werden dann vollautomatisch erkannt und in ein gewünschtes Datenbankformat geschrieben (SQL-Server, Oracle, MySQL, CSV, SPSS, XML, XLS, TXT, ASCII etc.). Anschließend können die Daten dann für die statistische Auswertung als auch die Übergabe an nachgelagerte Systeme verwendet werden. TeleForm ist modular aufgebaut: Designer, Scan Station, Reader, Verifier, AutoMerge Publisher, Control-Center, Exporter. Wir unterstützen Unternehmen und öffentliche Einrichtungen aus den unterschiedlichsten Bereichen: von Produktionsbetrieben, Forschungsstudien an Universitäten/Hochschulen bis hin zur öffentlichen Verwaltung. Als kompetenter und erfahrener Partner begleiten wir unsere Kunden von der Bedarfsanalyse bis zum Praxisbetrieb und verfügen über ein umfassendes Schulungsprogramm.
Workshop

Workshop

"Mit unseren Workshop- und Trainingsangeboten versetzen Sie Ihre Mitarbeiter in die Lage, mithilfe von additiver Fertigung Kosten- sowie Technikpotentiale zu identifizieren.
200ADM-P Secondary Current Injection Test Set

200ADM-P Secondary Current Injection Test Set

The 200ADM-P is a current injection system with a wide range of advanced features including phase shift, data storage and harmonic analysis. 0-200A output current True RMS metering with 1 cycle capture Variable auxiliary ac voltage/ current output with phase shift Auxiliary metering input V, f, Φ, Z, P, S, PF, CT ratio, harmonics & more Variable auxiliary output 12-220Vdc Multi-function auto-ranging timing system Current limit mode for fine control Data storage to USB memory key including waveform & harmonics USB keyboard/printer interface Automatic mains voltage selection The 200ADM-P Secondary Current Injection Test Set has a range of outputs allowing injection of currents between 1mA and 200A. Voltages up to 240V are available on the main outputs allowing high impedance current relays to be tested. True RMS metering with single cycle capture is provided. 4 current ranges allow the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used throughout for safe, reliable convenience. The 200ADM-P Secondary Current Injection Test Set has a flexible auxiliary ac output that can be used at up to 260V for voltage relays or up to 10A for current relays. The phase and frequency of this output are fully adjustable. This combination of voltage and current allows testing of relays that require two voltages, one voltage and one current or two currents. An auxiliary metering module is provided that meters ac and dc voltage, current and frequency from the auxiliary outputs or external signals. The module can also take measurements in conjunction with the main current output to meter phase angle, power, impedance, CT ratio and harmonics. A variable stabilised DC supply with current limit is provided to power the relay under test. WEIGHT 22.6 kg DIMENSIONS 500 × 456 × 265 mm SUPPLIED ACCESSORIES Operating manual Output lead set Mains lead Sparefuses USB keyboard USB memory key Shoulder strap (except Pelicase unit) OPTIONAL ACCESSORIES 100ADM-F, Part no. 006 100AL Mk2 / Mk3, Part no. A199-0003
18kV 10mA DC Tester PT18-10 MK2

18kV 10mA DC Tester PT18-10 MK2

Ultra lightweight (6.9kg) 1-200Adc test current with <2.5% ripple Supplied with standard 3m output lead set 0.1μΩ resolution mV, A, and m/μΩ displayed simultaneously USB memory key for data storage USB keyboard for comment entry Pre-settable test current with three buttons to store user test currents Large back-lit liquid crystal display Universal supply voltage 90-264V Optional current clamp to allows testing of objects with both sides earthed The PT18-10 mk2 high voltage dc test set is designed to perform tests on installed cable and jointing systems. The 18kV 10mA DC Tester has a variable output voltage with a maximum of ±18kVdc with a maximum charging capability of 10mA. A zero-volt interlock is fitted that prevents the output being switched on unless the output control is at zero. Units include an automatic load discharge system that discharges the cable under test when the output is switched off or a breakdown occurs. Internal dumping system can discharge a maximum of 2.5kJ on each output, corresponding to 10µF at 18kV. In the event of a test object failure, the overload circuit will automatically switch off the output voltage and earth the output via the internal discharge circuit. A DP20 discharge probe is supplied as standard with the PT18-10 mk2, 18kV 10mA DC Tester, allowing higher load capacitances to be safely discharged. The 18kV 10mA DC Tester has an internal fail-safe automatic discharge system with the following ratings: Max. discharge voltage (kVdc) 20kVdc Highest discharge energy 2.5kJ Highest discharge capacitance 10μF Max. discharges per hour 4 The automatic discharge switch is controlled by a solenoid. It may produce a noticeable hum when the HT output is energised. Output voltage is metered by two large, linear, analogue instruments marked 0-20kV. Meanwhile, current is metered by two further analogue instruments with 0-10 scale marking. The meters read 0-10mA directly, or 0-1mA when the ÷10 push button is operated. The HV output from the unit uses a high quality plug and socket system, allowing for easy cable replacement. High voltage plugs are protected in transit by plastic covers and are fully de-mountable. Screened 5 metre long high voltage output cables are provided with the equipment terminated with large clips. The mk2 units introduce automatic 115/230V mains voltage selection. That along the padded bag ensure maximum protection during transit.
TDX 5000 Tan Delta and capacitance test set

TDX 5000 Tan Delta and capacitance test set

TDX 5000 is developed as a compact solution for high voltage Capacitance and Tan Delta (Dissipation Factor) measurements. Using the reactor option, TDX 5000 can also perform tests on rotating machines. Main features Fully automatic Variable output frequency: 1 – 500 Hz Output voltage up to 12 kV Tan Delta, capacitance, dissipation factor measurements and exciting current test RCTD – compensating reactor module allows increasing the test current and getting the maximum test voltage with high capacitive burdens PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report USB interface and Ethernet interface for PC connection Patented technology for capacitance and Tan Delta measurement Light and compact Tests performed Tangent Delta Capacitance
100ADM MK5 Secondary Current Injection Test Set

100ADM MK5 Secondary Current Injection Test Set

0-100A output current True RMS metering with single cycle capture Auxiliary DC and AC output Multi-function auto-ranging timing system Current limit mode for fine control Automatic mains voltage selection Thermal and over-current protection The 100ADM mk5 Secondary Current Injection Test Set provides commissioning and maintenance engineers with a flexible system for testing protective systems. It has an easy to understand panel layout and a simple user interface. The status of every function can be seen at a glance, and there are no complex menus to navigate. The 100ADM mk5 keeps the familiar user interface of previous models but adds a new metering system that accurately measures the RMS of a single cycle. It also features a new current limit mode to provide very fine control of very low currents, even into low impedance loads. Current limit mode also assists in testing self-powered overcurrent protection as fitted to many 11kV ring main units. The unit has a range of outputs allowing injection of currents as low as a few mA and as high as 100A. Voltages up to 240V are available on the main outputs, allowing high impedance current relays and voltage relays to be tested. Four true RMS metering ranges are provided, allowing the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used on all inputs and outputs for convenience, reliability and safety. The 100ADM Mk5 Secondary Current Injection Test Set is comprehensively protected by overcurrent, duty cycle and thermal trips, and keeps the user fully informed of any trip condition. A stabilised DC supply is provided to power the relay under test, along with an independently switched and isolated 110V AC output. The back-lit display on the 100ADM mk5 is bright and clear with a wide viewing angle. The results of a test can be seen here as they appear on the display A very flexible two channel timing system is provided, allowing trip times, reset times and re-close times to be quickly measured to a high degree of accuracy. The timer auto-ranges to measure from 1ms to 99999.9s. The 100ADM can be used to test many types of single phase secondary protection including: 27/59 Over and under voltage relays 37 Under current 51 IDMT relays 50/76 Instantaneous overcurrent 59G Neutral voltage displacement 79 Auto-reclosers 2 Time delay relays 51G/50G Earth fault relays 67 Directional overcurrent (basic tests) 52 Miniature circuit breakers Tripping relays Thermal relays 90V Voltage regulating relays WEIGHT 23.9 kg DIMENSIONS 560 × 456 × 265 mm SUPPLIED ACCESSORIES Operating manual Mains lead Output lead set Spare fuses Carry strap OPTIONAL ACCESSORIES 100ADM-F, Part no. 006
PCU1-SP MK2 Primary Current Injection Test Set

PCU1-SP MK2 Primary Current Injection Test Set

5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switching 200A, 2000A and 5000A loading units Three range outputs on loading units Rugged, compact design Optional trolley mounting of system Secondary injection up to 100A Auxiliary metering input Direct reading CT ratio and polarity The PCU1-SP mk2 is a medium powered primary current injection set offering output currents up to 5000A (11.5kVA for 40seconds). The system consists of a separate control unit containing all metering and control functions and a loading unit, such as the NLU200, NLU2000 or the NLU5000, that provides the high current output. The PCU1-SP mk2 are ideally suited to primary current injection, stability testing and circuit breaker testing. In addition, the SP version offers direct-reading CT ratio and polarity tests and a 100A secondary injection output. Two loading units are available, delivering a maximum output current of 2000A or 5000A. Each loading unit has three output taps to allow for a wide range of load impedances. For example, the NLU5000 may be configured to either give a maximum current of 5000A on the 2.3V range, 2500A on the 4.6V range or 1250A on the 9.2V range. *The above is an image of the PCU1-SP and Loading Unit The control unit is rated at 11.5kVA with a 2 second overload capability of 23kVA using pulse mode. All metering is digital and a memory facility is provided to hold the current reading when the output trips or is switched off. The current is switched by a solid state device and is automatically switched off when the device under test trips. The PCU1-SP systems have a high accuracy timing system, allowing timing tests to be carried out to a resolution of 1ms. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available to test under and over current devices, re-closers, under and over voltage devices, current trips and circuit breakers. A full range of high current output leads are available to complement the system in a range of lengths. WEIGHT 26 kg DIMENSIONS 450 × 275 × 305 mm SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse set OPTIONAL ACCESSORIES Trolley mounting system, Part no A204-0005 100ADM-F, Part no. 006 100AL MK2 / MK3 Lead Set, Part no. A199-0003
HV TROLLEY2 High Voltage AC Test System

HV TROLLEY2 High Voltage AC Test System

20kVA output capability 0-3kV to 0-15kV options available Accurate digital metering Key operated supply switch Dual overload protection Variable electronic trip 10-110% of rated output Voltage and current metering Optional 5s – 5min test timer External 24V interlock and zero-volt interlock Emergency stop switch The HV trolley2 series of units are high power AC flash test sets with a 20kVA output capability. Single Trolley Version The maximum output voltage can be customised to be any voltage up to 15kV. The unit is housed in a rugged aluminium enclosure with a cover to protect the control panel. It is mounted on wheels to allow easy movement within a production environment. The HV trolley2 is provided with accurate digital voltage and current metering and a variable electronic trip. An external interlock input is also fitted to the unit. Outputs are provided to drive 24V warning beacons. The HV output is connected to the test object by a high voltage cable 5m long.
T 1000 PLUS Secondary injection relay test set

T 1000 PLUS Secondary injection relay test set

Multi-tasking test set designed for testing relays and transducers Max current output: 250 A Max AC voltage output: 250 V Max DC voltage output: 300 V Frequency generator: 15 ÷ 550 Hz Phase angle shifter Battery simulator 20 ÷ 260 V DC Oscilloscope function for current and voltage USB port – Microprocessor controller Test results and settings saved into local memory TD 1000 Plus model with two current outputs and high power at 15 Hz. T1000 PLUS is a protective relay test set especially designed to give the commissioning engineers a multitasking and highly reliable testing equipment. Tests performed Distribution relays Smart grid relays Single phase relays High burden relays
Stoil Cell For dielectric oil test

Stoil Cell For dielectric oil test

Oil cell for the HV test of dielectric oil The option allows the testing of the insulation characteristics of the oil by checking if there is no contamination. Main features Maximum test voltage: 12 kV Cell volume: about 1l Capacitance of the empty cell: 60 pF. Tests performed Tangent Delta
CU-Ps Primary Current Injection Test Set

CU-Ps Primary Current Injection Test Set

5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switching 200A, 2000A and 5000A loading units Three range outputs on loading units Rugged, compact design Optional trolley mounting of system Secondary injection up to 100A Auxiliary metering input Direct reading CT ratio and polarity The CU-Ps primary current injection test set is ideally suited to commissioning and maintenance testing where very high currents are required. The system consists of separate control and loading units for maximum flexibility. The control unit contains all control and metering circuitry, and is linked to the loading unit by control and metering cables. The control unit may be used with one of two loading units providing between 5000A or 6000A for 5 minutes or up to 10 or 12kA for short periods. Each loading unit has two outputs which may be connected in series or parallel for maximum flexibility. For example, the PLU-6k may be configured to either give a maximum current of 3000A at 6.6V or 6000A at 3.3V. The control and loading units are each housed in tough steel cases fitted with castors and protective lifting handles. The loading units have a small plan area to allow them to be positioned as close as possible to the test object, minimising power requirements and maximising the available current. The CU-Ps control unit is shown here with a PLU-6k loading unit. This combination may be used to inject currents of up to 6000A for 5 minutes or 12000A for 1 second. The CU-Ps primary current injection test set is ideally suited to all primary current injection tasks, including testing under and over current relays, circuit breakers and CT ratio testing. The control unit is rated at 20kVA and has digital metering. A memory facility is provided on the metering to hold the current reading when the output trips or is switched off. The current is automatically switched off when the device under test trips. The CU-Ps systems have a high accuracy timing system with 1ms resolution. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available for under and over current devices, reclosers, under and over voltage devices, current trips and circuit breakers. The AC output current is metered by a true RMS memory ammeter (acquisition time 20ms) with a liquid crystal display. The current metering has 3 ranges corresponding to 10%, 50% and 100% of the maximum rating of the loading unit. In addition, a 200% metering range is enabled in pulse mode for the 0.2s, 0.5s and 1s settings only. The CU-Ps systems have a flexible timing system with two contact inputs and 5 operating modes. Each contact circuit automatically selects for N/O or N/C contacts, and the status of each contact input is shown by an LED. The timing channels may also be triggered by a dc voltage between 24 and 240V. *Pulse mode applies current to the load for a maximum of the specified time. If contact set 1 changes state or the current drops below 20% of the metering range during the pulse time, the timer is stopped. The maximum output current is increased in pulse mode. The maximum obtainable current is set by the impedance of the test object and output leads. **Current operated mode is used to time circuit breakers with no auxiliary contacts. The timer is started when the current exceeds 20% of the selected metering range (e.g. 1000A on the PLU-5k 5000A range). The timer stops when the current falls. All test results from the CU-Ps can be stored in a USB memory key. The unit has a real-time clock to time and date-stamp all results. To log the results, first enter a comment for your results using the optional keyboard, and then select AUTO STORE. Whenever the timer stops, the time, current and all other parameters are added to a spreadsheet file on the USB key. You can then view the current set of results on the display or take the USB key out and open the file on your PC. All results are stored in a folder on the USB key named with the test date in a file named with the time. The CU-Ps primary current injection test sets and loading units are CE marked and are designed to meet the requirements of BS EN61010. The system is protected by electronic trips on the outputs, circuit breaker and fuse on the mains input, and a circuit breaker on the control unit output. The unit also has a duty cycle trip on the loading unit output and thermal protection. WEIGHT 115 kg DIMENSIONS 660 × 400 × 740 mm OPTIONAL ACCESSORIES A range of output lead sets are available to complement the CU-Ps system with current ratings between 3000A and 6000A. The leads are double insulated and have good flexibility. SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse set
Bump Tester und Gas Kalibrator

Bump Tester und Gas Kalibrator

Gesetzliche Vorschriften und die Notwendigkeit des täglichen Stoßprüfens erzeugen ein starkes Bedürfnis von Gastests. Gasdetektoren spielen eine wichtige Rolle für die Sicherheit von Menschen und Anlagen. Calibration Gas Description Ni-Br regulator Stainless steel regulator Non-reactive gases Suitable Suitable H2S Suitable Suitable SO2 Suitable Suitable NO Not recommended Suitable NO2 Not recommended Suitable Cl2 Not suitable Suitable NH3 Not suitable Suitable HCL Not suitable Suitable PH3 Not suitable Suitable SiH4 Not suitable Suitable HCN Not suitable Suitable
DRTS 6 Automatic relay test set

DRTS 6 Automatic relay test set

Main features Multi-tasking relay test equipment designed for testing protection relays, energy meters, transducers Output: 6×15 A (80 VA); 4×300 V (85 VA); 1×260 V DC High accuracy outputs: 0.1 %; 0.05% (HP) Analog measurement inputs IEC 61850 protocol interface USB and RS232 port Controlled by PC laptop or local control by PDA Tests performed Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays Low power relays DC relays Energy meters Transducers Power quality meters
DRTS 3 PLUS Automatic relay test set

DRTS 3 PLUS Automatic relay test set

DRTS 3 PLUS power system simulator is designed to give the highest accuracy when testing and calibrating protective relays, energy meter, transducer and power quality devices. This diagnostic and calibration equipment is the perfect solution to perform automatic testing on protection devices. Main features Multi-tasking relay test equipment designed for testing protection relays, energy meters, transducers Output: 3×15 A (100 VA); 4×300 V (85 VA); 1×260 V DC High accuracy: better than 0,05% Analog measurement inputs IEC 61850 communication Protocol interface USB and RS232 port Controlled by PC laptop or local control by PDA Lightweight Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays Low power relays DC relays Energy meters Transducers Power quality meters
DRTS 66 – Automatic relay test set

DRTS 66 – Automatic relay test set

DRTS 66 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 6 Current and 6 Voltage generators simultaneously available. Main features Manual control of the display 6 Current and 6 Voltage generetors plus 1 battery simulator outputs Current outputs : 6 x 32 A, 3 x 64 A, 1 x 128 A Power outputs: 6 x 430 VA, 3 x 860 VA, 1 x 1000 VA Voltage outputs: 6 x 300 V at 100 VA High accuracy outputs: better than 0.05% IEC 61850 protocol interface USB and ethernet interface Advanced testing and data management software TDMS Complete library of relays from the major manufacturers Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays High burden relays Low power relays DC relays Energy meters Transducers Power quality meters
DRTS 66 – Automatic relay test set

DRTS 66 – Automatic relay test set

DRTS 66 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 6 Current and 6 Voltage generators simultaneously available. Main features Manual control of the display 6 Current and 6 Voltage generetors plus 1 battery simulator outputs Current outputs : 6 x 32 A, 3 x 64 A, 1 x 128 A Power outputs: 6 x 430 VA, 3 x 860 VA, 1 x 1000 VA Voltage outputs: 6 x 300 V at 100 VA High accuracy outputs: better than 0.05% IEC 61850 protocol interface USB and ethernet interface Advanced testing and data management software TDMS Complete library of relays from the major manufacturers Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays High burden relays Low power relays DC relays Energy meters Transducers Power quality meters