Finden Sie schnell kabel kabel für Ihr Unternehmen: 1103 Ergebnisse

RE-2YCYSWAY-fl-PIMF

RE-2YCYSWAY-fl-PIMF

INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, It can be manufacture as RE-2Y(St)CYSWAY-PIMF upon request. Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: Braid of tinned Cu wires, 85% coverage Inner sheath: PVC compound, EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
BayEnergy®  N2XH-O  0,6/1 kV  3 ¹/₂

BayEnergy® N2XH-O 0,6/1 kV 3 ¹/₂

Starkstromkabel mit verbessertem Verhalten im Brandfall, halogenfrei, flammwidrig und raucharm z.B. für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Kabel mit verbessertem Verhalten im Brandfall. Im Innen- und Außenbereich, im Freien (vor Sonneneinstrahlung geschützt), jedoch nicht direkt in der Erde, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist, (siehe DIN VDE 0298-1).
BayEnergy®  N2XCH 0,6/1 kV 4 ¹/₂

BayEnergy® N2XCH 0,6/1 kV 4 ¹/₂

Starkstromkabel mit verbessertem Verhalten im Brandfall, halogenfrei, flammwidrig und raucharm z.B. für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Kabel mit verbessertem Verhalten im Brandfall. Im Innen- und Außenbereich, im Freien (vor Sonneneinstrahlung geschützt), jedoch nicht direkt in der Erde, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1). Die EMV Konstruktion wird speziell im 4½-Leitersystem TN-S mit einem getrennten Neutralleiter (N) und Schutzleiter (PE) eingesetzt. Dies ermöglicht ein EMV-optimiertes Versorgungsnetz zur Reduzierung der elektromagnetischen Störungen. Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur und eine höhere Belastbarkeit im Kurzschlussfall als vergleichbare Kabel mit PVC-Aderisolierung.
BayEnergy® N2XS2Y 0,6/1 kV

BayEnergy® N2XS2Y 0,6/1 kV

Kabel für besondere Anwendungen, z. B. als einadrige Bahnspeisekabel für Gleich- und Wechselstrombahnen und zur Bahnstromrückführung in Gleichstromsystemen für Spannungen bis 0,6/1 kV. Vorzugsweise für Verbindungen im Fahrleitungs- und Gleisbereich, zur Verlegung in Rohr- und Trogkanälen und direkt in Erde. Für die Auswahl der Bahnstromkabel gelten die Vorgaben der Verkehrsbetriebe. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung.
BayEnergy®  N2XH-J  0,6/1 kV  vieladrig

BayEnergy® N2XH-J 0,6/1 kV vieladrig

Starkstromkabel mit verbessertem Verhalten im Brandfall, halogenfrei, flammwidrig und raucharm z.B. für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Kabel mit verbessertem Verhalten im Brandfall. Im Innen- und Außenbereich, im Freien (vor Sonneneinstrahlung geschützt), jedoch nicht direkt in der Erde, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist, (siehe DIN VDE 0298-1).
BayEnergy® N2XCY 0,6/1 kV  4 ¹/₂

BayEnergy® N2XCY 0,6/1 kV 4 ¹/₂

Starkstromkabel für höhere Leitertemperaturen zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Innen- und Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1). Die EMV Konstruktion wird speziell im 4 1/2-Leitersystem TN-S mit einem getrennten Neutralleiter (N) und Schutzleiter (PE) eingesetzt. Dies ermöglicht ein EMV-optimiertes Versorgungsnetz zur Reduzierung der elektromagnetischen Störungen. Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur und eine höhere Belastbarkeit im Kurzschlussfall als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
BayEnergy®  N2XH-O  0,6/1 kV  vieladrig

BayEnergy® N2XH-O 0,6/1 kV vieladrig

Starkstromkabel mit verbessertem Verhalten im Brandfall, halogenfrei, flammwidrig und raucharm z.B. für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Kabel mit verbessertem Verhalten im Brandfall. Im Innen- und Außenbereich, im Freien (vor Sonneneinstrahlung geschützt), jedoch nicht direkt in der Erde, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist, (siehe DIN VDE 0298-1).
BayEnergy®  NYY-J  0,6/1 kV  3 ¹/₂

BayEnergy® NYY-J 0,6/1 kV 3 ¹/₂

Starkstromkabel für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze, falls kein erhöhter mechanischer Schutz erforderlich ist (siehe DIN VDE 0298-1). Kabel mit verbessertem Verhalten im Brandfall. Im Innen- und Außenbereich, im Freien (vor Sonneneinstrahlung geschützt), jedoch nicht direkt in der Erde, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist, (siehe DIN VDE 0298-1).
RE-2Y(St)H & RE-2X(St)H-MP

RE-2Y(St)H & RE-2X(St)H-MP

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 Capacitance unbalance: (1 kHz) : max. 500 pF/500 m Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Min. bending radius: 7,5 x D Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4
BayEnergy®  NYCY  0,6/1 kV  4+1-adrig

BayEnergy® NYCY 0,6/1 kV 4+1-adrig

Starkstromkabel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. Im Innen- und Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1). Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen
BaySpecial®  NAEKEBA  21/36 kV  3-adrig

BaySpecial® NAEKEBA 21/36 kV 3-adrig

Massekabel/Dreibleimantelkabel für die Verlegung im Freien und im Erdreich, insbesondere für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze. Im Freien und im Erdreich für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl

RE-Y(St)Y-fl & RE-Yw(St)Yw-fl

INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, PVC INSULATED, COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. For application of 105oC heat resistant, RE-Yw(St)Yw cables are suitable. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (Y): PVC compound, 70 oC grade; EN 50290-2-21 Insulation (Yw): PVC compound, 105 oC grade; EN 50290-2-21 Core identification: Black / Blue / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Outer sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1 Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 100 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 105 oC, ınstallation : - 5 oC ~ + 50 oC
BayEnergy®  NAYCWY  0,6/1 kV  4+1-adrig

BayEnergy® NAYCWY 0,6/1 kV 4+1-adrig

Starkstromkabel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. In Innenräumen und Kabelkanälen, im Freien, im Erdreich für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1). Die EMV+ Konstruktion wird speziell im 4+1 Leitersystem TN-S mit einem getrennten Neutralleiter (N) und querschnittsgleichem Schutzleiter (PE) eingesetzt. Durch den besseren Leitwert im PE-Leiter werden EMV-Störungen optimal reduziert und bieten einen höheren Schutz als bei Kabeln mit reduziertem Außenleiter (4½-Leiter). Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
BaySpecial®  NAEKEBA  12/20 kV  3-adrig

BaySpecial® NAEKEBA 12/20 kV 3-adrig

Massekabel/Dreibleimantelkabel für die Verlegung im Freien und im Erdreich, insbesondere für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze. Im Freien und im Erdreich für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
RE-2Y(St)YSWAY-fl & RE-2X(St)YSWAY-fl

RE-2Y(St)YSWAY-fl & RE-2X(St)YSWAY-fl

INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)YSWAY-fl,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, PVC SHEATHEDRE-2X(St)YSWAY-fl,SINGLE & MULTI-TRIPLE, XLPE INSULATED, COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Inner sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Inner sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Outer sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
BayEnergy®  NYCWY  0,6/1 kV  4+1-adrig

BayEnergy® NYCWY 0,6/1 kV 4+1-adrig

Starkstromkabel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. Im Innen- und Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist (siehe DIN VDE 0298-1). Die EMV+ Konstruktion wird speziell im 4+1 Leitersystem TN-S mit einem getrennten Neutralleiter (N) und querschnittsgleichem Schutzleiter (PE) eingesetzt. Durch den besseren Leitwert im PE-Leiter werden EMV-Störungen optimal reduziert und bieten einen höheren Schutz als bei Kabeln mit reduziertem Außenleiter (4½-Leiter). Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
BaySpecial®  NAEKEBA  18/30 kV  3-adrig

BaySpecial® NAEKEBA 18/30 kV 3-adrig

Massekabel/Dreibleimantelkabel für die Verlegung im Freien und im Erdreich, insbesondere für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze. Im Freien und im Erdreich für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
BayEnergy®  N2XCH 0,6/1 kV 3-adrig

BayEnergy® N2XCH 0,6/1 kV 3-adrig

Starkstromkabel mit verbessertem Verhalten im Brandfall, halogenfrei, flammwidrig und raucharm z.B. für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Kabel mit verbessertem Verhalten im Brandfall. Im Innen- und Außenbereich, im Freien (vor Sonneneinstrahlung geschützt), jedoch nicht direkt in der Erde, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1).
RE-2Y(St)Y-fl & RE-2X(St)Y-fl

RE-2Y(St)Y-fl & RE-2X(St)Y-fl

INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)Y-fl,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, PVC SHEATHEDRE-2X(St)Y-fl,SINGLE & MULTI-TRIPLE, XLPE INSULATED, COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Outer sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1
BaySpecial®  NEKEBA  12/20 kV  3-adrig

BaySpecial® NEKEBA 12/20 kV 3-adrig

Massekabel/Dreibleimantelkabel für die Verlegung im Freien und im Erdreich, insbesondere für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze. Im Freien und im Erdreich für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
BaySpecial®  NEKEBA  18/30 kV 3-adrig

BaySpecial® NEKEBA 18/30 kV 3-adrig

Massekabel/Dreibleimantelkabel für die Verlegung im Freien und im Erdreich, insbesondere für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze. Im Freien und im Erdreich für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
BayEnergy®  NYY-O  0,6/1 kV  4-5-adrig

BayEnergy® NYY-O 0,6/1 kV 4-5-adrig

Starkstromkabel für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze, falls kein erhöhter mechanischer Schutz erforderlich ist (siehe DIN VDE 0298-1). Im Innen- und Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist (siehe DIN VDE 0298-1). Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
BayEnergy®  N2XCWY  0,6/1 kV  4+1-adrig

BayEnergy® N2XCWY 0,6/1 kV 4+1-adrig

Starkstromkabel für höhere Leitertemperaturen zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Innen- und Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist (siehe DIN VDE 0298-1). Die EMV+ Konstruktion wird speziell im 4+1 Leitersystem TN-S mit einem getrennten Neutralleiter (N) und querschnittsgleichem Schutzleiter (PE) eingesetzt. Durch den besseren Leitwert im PE-Leiter werden EMV-Störungen optimal reduziert und bieten einen höheren Schutz als bei Kabeln mit reduziertem Außenleiter (4½-Leiter). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur und eine höhere Belastbarkeit im Kurzschlussfall als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
BayEnergy® N2X2Y-J  0,6/1 kV  vieladrig

BayEnergy® N2X2Y-J 0,6/1 kV vieladrig

Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den HDPE-Außenmantel besonders widerstandsfähig. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
BayEnergy®  NYY-J  0,6/1 kV  4-5-adrig

BayEnergy® NYY-J 0,6/1 kV 4-5-adrig

Starkstromkabel für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze, falls kein erhöhter mechanischer Schutz erforderlich ist (siehe DIN VDE 0298-1). Im Innen- und Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist (siehe DIN VDE 0298-1). Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
BayEnergy® N2X2Y-O  0,6/1 kV  vieladrig

BayEnergy® N2X2Y-O 0,6/1 kV vieladrig

Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den HDPE-Außenmantel besonders widerstandsfähig. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
BayEnergy®  N2XCWH  0,6/1 kV  4 +1-adrig

BayEnergy® N2XCWH 0,6/1 kV 4 +1-adrig

Starkstromkabel mit verbessertem Verhalten im Brandfall, halogenfrei, flammwidrig und raucharm z.B. für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Kabel mit verbessertem Verhalten im Brandfall. Im Innen- und Außenbereich, im Freien (vor Sonneneinstrahlung geschützt), jedoch nicht direkt in der Erde, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1). Die EMV+ Konstruktion wird speziell im 4+1 Leitersystem TN-S mit einem getrennten Neutralleiter (N) und querschnittsgleichem Schutzleiter (PE) eingesetzt. Durch den besseren Leitwert im PE-Leiter werden EMV-Störungen optimal reduziert und bieten einen höheren Schutz als bei Kabeln mit reduziertem Außenleiter (4½-Leiter). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur und eine höhere Belastbarkeit im Kurzschlussfall als vergleichbare Kabel mit PVC-Aderisolierung.
BayEnergy® N2X2Y-J  0,6/1 kV  3 ¹/₂

BayEnergy® N2X2Y-J 0,6/1 kV 3 ¹/₂

Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den HDPE-Außenmantel besonders widerstandsfähig. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
BayEnergy® NA2XCWY  0,6/1 kV  4+1-adrig

BayEnergy® NA2XCWY 0,6/1 kV 4+1-adrig

Starkstromkabel für höhere Leitertemperaturen zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. In Innenräumen und Kabelkanälen, im Freien, im Erdreich für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die EMV+ Konstruktion wird speziell im 4+1 Leitersystem TN-S mit einem getrennten Neutralleiter (N) und querschnittsgleichem Schutzleiter (PE) eingesetzt. Durch den besseren Leitwert im PE-Leiter werden EMV-Störungen optimal reduziert und bieten einen höheren Schutz als bei Kabeln mit reduziertem Außenleiter (4½-Leiter). Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
BayEnergy® N2X2Y-O  0,6/1 kV  3 ¹/₂

BayEnergy® N2X2Y-O 0,6/1 kV 3 ¹/₂

Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den HDPE-Außenmantel besonders widerstandsfähig. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.