INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)Y-fl,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, PVC SHEATHEDRE-2X(St)Y-fl,SINGLE & MULTI-TRIPLE, XLPE INSULATED, COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Outer sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1
Ähnliche Produkte
1/15
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl
INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, PVC INSULATED, COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of a...
DE-72175 Dornhan
RE-2Y(St)Y-fl
RE-2Y(St)Y-fl
INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1SİNGLE & MULTİ-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for...
DE-72175 Dornhan
RE-2Y(St)H&RE-2X(St)H
RE-2Y(St)H&RE-2X(St)H
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1RE-2Y(St)H,SİNGLE & MULTİ-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHEDRE...
DE-72175 Dornhan
RE-2Y(St)Y-fl & RE-2X(St)Y-fl MP
RE-2Y(St)Y-fl & RE-2X(St)Y-fl MP
INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)Y-fl,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, PVC SHEATHEDRE-2X(St)Y-fl,SINGLE & MULTI-PAIR,...
DE-72175 Dornhan
RE-2Y(St)H & RE-2X(St)H
RE-2Y(St)H & RE-2X(St)H
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & M...
DE-72175 Dornhan
RE-2Y(St)Y-fl-MP
RE-2Y(St)Y-fl-MP
INSTRUMENTATION CABLES, BS 5308 PART 1 TYPE 1SİNGLE & MULTİ-PAİR, PE INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmiss...
DE-72175 Dornhan
RE-2Y(St)Y & RE-2X(St)Y
RE-2Y(St)Y & RE-2X(St)Y
INSTRUMENTATION CONTROL CABLES, EN 50288-7RE-2Y(St)Y,ÇOK DAMARLI, PE YALITIMLI, GENEL EKRANLI, PVC KILIFLIRE-2X(St)Y,ÇOK DAMARLI, XLPE YALITIMLI, GENE...
DE-72175 Dornhan
RE-2Y(St)Y-fl-TIMF & RE-2X(St)Y-fl-TIMF
RE-2Y(St)Y-fl-TIMF & RE-2X(St)Y-fl-TIMF
INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)Y-fl-TIMF,MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHEDRE-2X(St)Y-fl-TIMF,MULT...
DE-72175 Dornhan
RE-2Y(St)Y-fl-TIMF
RE-2Y(St)Y-fl-TIMF
INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHED These cables are used...
DE-72175 Dornhan
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl MP
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl MP
INSTRUMENTATION CABLES, EN 50288-7SİNGLE & MULTİ-PAİR, PVC INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmission of ana...
DE-72175 Dornhan
RE-2G(St)H-CI  FE180
RE-2G(St)H-CI FE180
HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, SILICONE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHED Thes...
DE-72175 Dornhan
RE-Y(St)Y-fl-MP
RE-Y(St)Y-fl-MP
INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 1SİNGLE & MULTİ-PAİR, PVC INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmis...
DE-72175 Dornhan
RE-Y(St)Y-fl
RE-Y(St)Y-fl
INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 1MULTİ-CORE, PVC INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmission of a...
DE-72175 Dornhan
RE-2Y(St)H-TIMF & RE-2X(St)H-TIMF
RE-2Y(St)H-TIMF & RE-2X(St)H-TIMF
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H-T...
DE-72175 Dornhan
RE-2Y(St)HSWAH & RE-2X(St)HSWAH
RE-2Y(St)HSWAH & RE-2X(St)HSWAH
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(S...
DE-72175 Dornhan