Finden Sie schnell golddetektor für Ihr Unternehmen: 7 Ergebnisse

Hyperspectral Imaging Cameras/ Spectrometer

Hyperspectral Imaging Cameras/ Spectrometer

LLA provides UV-VIS (350 nm - 950 nm) & NIR hyperspectral imaging cameras incl. illumination, calibration, installation bridge & comprehensive software tools for an immediate installation in a plant. VIS-NIR and SWIR Hyperspectral imaging cameras are widely used in industry for sorting purposes. The VIS-NIR model is available in 2 versions: ■ uniSPEC0.9HSI_w - enhanced spectral resolution version, 600nm effective spectral bandwidth, reduced number of spatial tracks and ■ uniSPEC0.9HSI_s - reduced spectral bandwidth of 400 nm, high spatial resolution version The NIR-SWIR models are avaible as 3 different camera types. ■ KUSTA1.7MSI / 0.95 µm – 1.7 µm ■ KUSTA1.9MSI / 1.32 µm– 1.9 µm ■ KUSTA2.2MSIsens / 1.62 µm– 2.19 µm With regard to plastics recycling, we recommend the integration of KUSTA1.7MSI or KUSTA1.9MSI into the sorting plant. The advantage of KUSTA1.9MSI is, the camera ideally suited for plastics recycling; PVC will be reliably detected as well as all other plastics. In combination with our accessories, our products were developed in terms of the best performance. Germany: Berlin Weight: 16kg IP: 67 Hyperspectral Imaging Camera Model: NIR-SWIR Hyperspectral Imaging Camera KUSTA1.7MSI Wavelength Range: 950 nm - 1700 nm
400 GD Multifunktionsdetektor und Messgerät

400 GD Multifunktionsdetektor und Messgerät

System: Lecksuche an Klimageräten (Kältemittel) Lecksuche an Gasinstallationen (Brennbare Gase) Lecksuche an Abgasanlagen (Abgasrückstau) Überprüfung von Raumklima (Feuchte, Temperatur, Luftdruck, Taupunkt) Berührungslose Temperaturmessung (Oberflächentemperatur) CO in Umgebung Herausragende Vorteile: Einstellbare Alarmschwellen Optischer Alarm am Sensor und im Gerätedisplay Akustischer Alarm und Vibrationsalarm durch das Messgerät Starker Lithium-Ionen Akku, aufladbar über Mini-USB-Buchse QR - Code Generierung für Mailversand der Messwerte
Differenzlehre zur Messung der Abnutzung der Kupplungsachse

Differenzlehre zur Messung der Abnutzung der Kupplungsachse

Differenzlehre wird zur Messung der Abnutzung der Kupplungsachse verwendet.
Hyperspectral Imaging Cameras/ Spectrometer

Hyperspectral Imaging Cameras/ Spectrometer

LLA provides VIS-NIR (350 nm - 950 nm) & NIR hyperspectral imaging cameras incl. illumination, calibration, installation bridge & comprehensive software tools for an immediate installation in a plant. VIS-NIR and SWIR Hyperspectral imaging cameras are widely used in industry for sorting purposes. The VIS-NIR model is available in 2 versions: ■ uniSPEC0.9HSI_w - enhanced spectral resolution version, 600nm effective spectral bandwidth, reduced number of spatial tracks and ■ uniSPEC0.9HSI_s - reduced spectral bandwidth of 400 nm, high spatial resolution version The NIR-SWIR models are avaible as 3 different camera types. ■ KUSTA1.7MSI / 0.95 µm – 1.7 µm ■ KUSTA1.9MSI / 1.32 µm– 1.9 µm ■ KUSTA2.2MSIsens / 1.62 µm– 2.19 µm With regard to plastics recycling, we recommend the integration of KUSTA1.7MSI or KUSTA1.9MSI into the sorting plant. The advantage of KUSTA1.9MSI is, the camera ideally suited for plastics recycling; PVC will be reliably detected as well as all other plastics. In combination with our accessories, our products were developed in terms of the best performance. Germany: Berlin Weight: 16kg IP: 67 Hyperspectral Imaging Camera Model: VIS-NIR Hyperspectral Camera Wavelength Range: 350 nm - 950 nm
Hyperspectral Imaging Cameras/ Spectrometer

Hyperspectral Imaging Cameras/ Spectrometer

LLA provides UV-VIS (350 nm - 950 nm) & NIR hyperspectral imaging cameras incl. illumination, calibration, installation bridge & comprehensive software tools for an immediate installation in a plant. VIS-NIR and SWIR Hyperspectral imaging cameras are widely used in industry for sorting purposes. The VIS-NIR model is available in 2 versions: ■ uniSPEC0.9HSI_w - enhanced spectral resolution version, 600nm effective spectral bandwidth, reduced number of spatial tracks and ■ uniSPEC0.9HSI_s - reduced spectral bandwidth of 400 nm, high spatial resolution version The NIR-SWIR models are avaible as 3 different camera types. ■ KUSTA1.7MSI / 0.95 µm – 1.7 µm ■ KUSTA1.9MSI / 1.32 µm– 1.9 µm ■ KUSTA2.2MSIsens / 1.62 µm– 2.19 µm With regard to plastics recycling, we recommend the integration of KUSTA1.7MSI or KUSTA1.9MSI into the sorting plant. The advantage of KUSTA1.9MSI is, the camera ideally suited for plastics recycling; PVC will be reliably detected as well as all other plastics. In combination with our accessories, our products were developed in terms of the best performance. Germany: Berlin Weight: 16kg IP: 67 Hyperspectral Imaging Camera Model: NIR-SWIR Hyperspectral Imaging Camera KUSTA1.9MSI Wavelength Range: 1320 nm - 1900 nm
Hyperspectral Imaging Cameras/ Spectrometer

Hyperspectral Imaging Cameras/ Spectrometer

LLA provides UV-VIS (350 nm - 950 nm) & NIR hyperspectral imaging cameras incl. illumination, calibration, installation bridge & comprehensive software tools for an immediate installation in a plant. VIS-NIR and SWIR Hyperspectral imaging cameras are widely used in industry for sorting purposes. The VIS-NIR model is available in 2 versions: ■ uniSPEC0.9HSI_w - enhanced spectral resolution version, 600nm effective spectral bandwidth, reduced number of spatial tracks and ■ uniSPEC0.9HSI_s - reduced spectral bandwidth of 400 nm, high spatial resolution version The NIR-SWIR models are avaible as 3 different camera types. ■ KUSTA1.7MSI / 0.95 µm – 1.7 µm ■ KUSTA1.9MSI / 1.32 µm– 1.9 µm ■ KUSTA2.2MSIsens / 1.62 µm– 2.19 µm With regard to plastics recycling, we recommend the integration of KUSTA1.7MSI or KUSTA1.9MSI into the sorting plant. The advantage of KUSTA1.9MSI is, the camera ideally suited for plastics recycling; PVC will be reliably detected as well as all other plastics. In combination with our accessories, our products were developed in terms of the best performance. Germany: Berlin Weight: 16kg IP: 67 Hyperspectral Imaging Camera Model: NIR-SWIR Hyperspectral Imaging Camera KUSTA2.2MSIsens Wavelength Range: 1620 nm - 2190 nm
Gerät zur Messung der Gleitachslager - Dimension C

Gerät zur Messung der Gleitachslager - Dimension C

Messung nach Messkarte der Dimension C von Gleitachslagern. Für Drehgestelle des Typs 1XT und 1XTa mit Änderungen. Die wichtigsten Parameter: Messbereich: 55 - 75mm Messgenauigkeit: 0,1mm