OECD 437 / OECD 438 / OECD 491 / OECD 492 / Eye Irritation / Eye damage hazard assessment / in vitro Test
OECD 437 / OECD 438 / OECD 491 / OECD 492 / Eye Irritation / Eye damage hazard assessment / in vitro TestOECD 437 / OECD 438 / OECD 491 / OECD 492 / Eye Irritation / Eye damage hazard assessment / in vitro Test

OECD 437 / OECD 438 / OECD 491 / OECD 492 / Eye Irritation / Eye damage hazard assessment / in vitro Test

Über dieses Produkt

WebsiteBesuchen Sie die Produktseite
Eye Irritation / Eye damage hazard assessment in vitro OECD 437, OECD 438, OECD 491, OECD 492, Het cam etc. Fast Project Execution: personal - competent - reliable --> contact@invitro-connect.com Strategies for Eye Irritation Testing Determination of ocular irritation potential is a key toxicological endpoint required to support chemical and raw material characterization and industrial hygiene, to guide product development, and to achieve final product safety standards. INVITRO-CONNECT possesses extensive experience with numerous test methods and testing strategies for commercial, industrial and regulatory applications. From standard regulatory hazard assessments to providing information on the degree of ocular irritation, to discriminating among extremely mild eye area products, INVITRO-CONNECT’ Study Monitors take the time to understand your specific goals and apply the most relevant, cost-effective strategies to achieve them. Tests for Eye Irritation / Eye damage hazard assessment in vitro: HET-CAM Assay BCOP: OECD 437 Isolated Chicken Eye Test: OECD 438 STE / Short Time Exposure (STE, OECD 491): Ocular Irritection EpiOcular & SkinEthic HCE Reconstructed human Cornea-like Epithelium (RhCE): OECD 492 Assessing Eye Sting-NociOcular Assay: Many personal care and cosmetic products accidentally contact the eye, which is very sensitive to numerous compounds that would otherwise be benign when applied to the skin. Due to the pain and stinging that is perceived, it is important for manufacturers of these products to be aware of the potential pain perceived should eye contact occur. Eye Irritation Test using Reconstructed Human Corneal Epithelium (RhCE) Models (EIT, OECD 492): The Eye Irritation Test (EIT) is an OECD-approved in vitro non-animal test method for identifying chemicals and mixtures that may be irritating to the corneal epithelium. The test method utilizes an in vitro reconstructed human corneal epithelium (RhCE) model (EpiOcular™, MatTek Corp. or HCE, SkinEthic™), in an acute exposure assay to support international regulatory labeling requirements, according to the United Nations Globally Harmonized System of Classification and Labelling of Chemicals (UN GHS). Eye Irritation Time-to-Toxicity Test using Reconstructed Human Corneal Epithelium (RhCE) Models: The ocular irritation potential of formulations, products, ingredients, and chemicals can be evaluated using in vitro reconstructed human corneal epithelium (RhCE) models, such as the EpiOcular™ (MatTek Corp.) and SkinEthic HCE (EPISKIN) organotypic 3-D tissue constructs. Whether evaluating ultra-mild cosmetics and personal care products, or rank ordering the irritation potential of candidate formulations and ingredients, we can provide custom Ocular Screening protocols to best meet your testing goals. Bovine Corneal Opacity and Permeability (BCOP, OECD 437) with Optional Histology: The BCOP (Bovine Corneal Opacity and Permeability) assay is an in vitro eye irritation test method developed by Gautheron et al. (1992), which uses living bovine corneal tissue, obtained as a by-product from abattoirs, to evaluate the potential ocular irritancy of a test article. Types of injury caused by exposure to the test article are quantitatively measured by changes in opacity and permeability to fluorescein. Short Time Exposure (STE, OECD 491): The Short Time Exposure (STE) assay, developed by Kao Corporation (Japan), is an in vitro assay used to assess acute eye irritation potential as an alternative to the traditional in vivo Draize test. The test method evaluates the cytotoxicity induced by a series of test chemical dilutions in a monolayer of rabbit corneal fibroblasts (Statens Seruminstitut Rabbit Cornea – SIRC) after a single five-minute exposure. CAMVA: The CAMVA is an in vitro assay that measures the presence and degree of vascular effect to the chorioallantoic membrane (CAM) of 10-day fertilized eggs following exposure to test article. Ocular Irritection (OIA): The Ocular Irritection Assay is an in chemico eye irritation assay that detects, ranks, and predicts the corneal irritation potential of a test material. The assay assesses changes to the reagent solution (containing proteins, glycoproteins, lipids), which mimics the denaturation and disruption that occurs in corneal proteins in vivo. Assessing Corneal Recovery: Corneal recovery is a key property of ocular irritation classification schemes used in the regulatory arena. However, no current validated non-animal ocular irritation test methods or prediction tools are able to predict corneal recovery in a manner consistent with the animal tests historically employed. Whereas some efforts have been made to demonstrate recovery with in vitro or ex vivo corneal models, the current state of these technologies do not support demonstration of recovery of the corneal stromal elements, which are key to discriminate between moderate and severe irritants.

Schlagwörter

Labortechnik
Ähnliche Produkte
1/15
19. Swiss Business & IT-Servicemanagement und Service Desk Forum
19. Swiss Business & IT-Servicemanagement und Service Desk Forum
Am 25. Mai 2022 Ort: Zürich Auf dem 19. Swiss Business- und IT-Servicemanagement und Service Desk Forum 2022 werden wieder topaktuelle Themen und Tren...
CH-4142 Münchenstein
Glasfaserkabel LWL Einblasen Jetting
Glasfaserkabel LWL Einblasen Jetting
Wir sind ausgerüstet für das Einblasen von Micro- und Minikabeln auf NE3 von MFG zu KVz zu HÜP mit Protokollierung. Wir vereinbaren in Zusammenarbeit...
DE-72160 Horb am Neckar
B2B-Connector - Die Online-Schnittstelle für optimal integrierte Prozesse
B2B-Connector - Die Online-Schnittstelle für optimal integrierte Prozesse
Der B2B-Connector ist die universelle Schaltzentrale zwischen Ihrer Online-Plattform und Ihren internen Systemen und Prozessen wie ERP, PIM, CRM und m...
DE-12555 Berlin
OneConnect™
OneConnect™
OneConnect™ von LINAK: Alles in EINER Hand. App für Kunden und Techniker, Cloud für Hilfe und Remote-Fehlerbehebung, Verwaltungsportal. LINAK Steuerei...
DE-63667 Nidda
Einfach, schnell und sicher zur prüffähigen Statik!
Einfach, schnell und sicher zur prüffähigen Statik!
COP ist eine innovative und benutzerfreundliche Software für die Bemessung von Anschlüssen in Stahlkonstruktionen. Die Berechnung erfolgt nach Eurocod...
DE-52076 Aachen
idealo Connector für Magento/Openmage
idealo Connector für Magento/Openmage
Mit dem offiziellen idealo Connector verbinden Sie Ihren Magento 1/2 Onlineshop direkt mit der Preisvergleichs-Plattform idealo. Mit dem offiziellen ...
DE-24118 Kiel
Telit IoT Starter SIM
Telit IoT Starter SIM
Automatisches Roaming in's stärkste Netz Artikelnummer: SER-STARTERSIM Lieferumfang: Keine Eintragung..., SER-STARTERSIM-FORM...
DE-63263 Neu-Isenburg
Schwingquarze, Oszillatoren, Resonatoren der Firma Jauch
Schwingquarze, Oszillatoren, Resonatoren der Firma Jauch
Seit 1985 handeln wir mit Quarzen, Schwingquarzen, Oszillatoren, Resonatoren, TCXO's und VCXO's der Firma Jauch. Rundsteckverbinder im Metall- oder Ku...
AT-2700 Wiener Neustadt
ConnectedWare
ConnectedWare
ConnectedWare - Where marketing gets done! ConnectedWare ist die modulare Marketing-Automatisations-Plattform für Marketingdatenbank, automatisiertes...
AT-4063 Hörsching
Select Partner: Heizung
Select Partner: Heizung
Fernwärme Heizungspumpen Heizungsentleerung Klemmringverschraubungen, Problemlöser Sockelleisten Fußbodenheizung Wohnungsstationen Luft-Schlammabschei...
DE-52249 Eschweiler
Select Partner: Heizung
Select Partner: Heizung
Fernwärme Heizungspumpen Heizungsentleerung Klemmringverschraubungen, Problemlöser Sockelleisten Fußbodenheizung Wohnungsstationen Luft-Schlammabschei...
DE-53119 Bonn
Select Partner: Heizung
Select Partner: Heizung
Fernwärme Heizungspumpen Heizungsentleerung Klemmringverschraubungen, Problemlöser Sockelleisten Fußbodenheizung Wohnungsstationen Luft-Schlammabschei...
DE-86161 Augsburg
Select Partner: Heizung
Select Partner: Heizung
Fernwärme Heizungspumpen Heizungsentleerung Klemmringverschraubungen, Problemlöser Sockelleisten Fußbodenheizung Wohnungsstationen Luft-Schlammabschei...
DE-45894 Gelsenkirchen
Select Partner: Heizung
Select Partner: Heizung
Fernwärme Heizungspumpen Heizungsentleerung Klemmringverschraubungen, Problemlöser Sockelleisten Fußbodenheizung Wohnungsstationen Luft-Schlammabschei...
DE-58095 Hagen
H.Meyer Voic Connect
H.Meyer Voic Connect
Voice Connect verbindet Ihre derzeitige Telefonanlage mit der hochmodernen Kommunikationsplattform von H.Meyer. Dabei bleiben alle Ihre gewohnten Fun...
DE-66130 Saarbrücken

Die wer liefert was (wlw)-App ist da!

Nutzen Sie unsere verbesserte Anbietersuche oder erstellen Sie Ihre Anfragen jetzt auch mobil mit der neuen wlw-App für Einkäufer.

Jetzt im App Store herunterladen

App StoreGoogle Play