50ADM-P Current Injection System with Phase Shift
50ADM-P Current Injection System with Phase Shift

50ADM-P Current Injection System with Phase Shift

Über dieses Produkt

WebsiteBesuchen Sie die Produktseite
0-50A output current True RMS metering with 1 cycle capture Variable auxiliary AC voltage/current output with phase shift Auxiliary metering input V, f, φ, Z, P, S, PF, CT ratio, harmonics Variable auxiliary output 12-220VDC Multi-function auto-range timing system Current limit mode for fine control Data storage to USB memory key including waveform & harmonics USB keyboard interface Automatic mains voltage selection Optional Backpack System The 50ADM-P is a smaller version of our current injection system the 200ADM-P. The unit has a range of outputs allowing injection of currents from 1mA to 50A. Voltages up to 18V are available on the main outputs. True RMS metering with single cycle capture is provided. Three current ranges allow the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used throughout for safe, reliable convenience. The 50ADM-P has a flexible auxiliary AC output that can be used at up to 260V for voltage relays or up to 10A for current relays. The phase and frequency of this output are fully adjustable. This combination of voltage and current allows testing of relays that require two voltages, one voltage and one current or two currents. An auxiliary metering input is provided that meters AC and DC voltage, current and frequency from the auxiliary outputs or external signals. The mod-ule can also take measurements in conjunction with the main current output to meter phase angle, power, impedance, CT ratio and harmonics. A variable stabilised DC supply with current limit is provided to power the relay under test. The unit has a comprehensive timing system linked to the outputs allowing trip times, reset times and reclose times to be quickly measured to a high degree of accuracy. The timer includes a current operated mode and can accurately test instantaneous trips. Two USB host sockets are provided to connect a memory key and keyboard. Results of every test can be stored to the memory key in spreadsheet format for later analysis. The keyboard allows entry of a comment against each result. In addition a graphics file of the waveform may be stored to the memory key. Harmonic analysis results can also be recorded.
Ähnliche Produkte
1/15
1200A-3PH 3 Phase Current Injection
1200A-3PH 3 Phase Current Injection
Clear and simple user interface 3-Φ current output 0-1200A per phase output current True RMS digital metering Memory ammeter Multi-function timin...
DE-16562 Hohen Neuendorf/OT Bergfelde
750ADM-H mk3 Current Injection System
750ADM-H mk3 Current Injection System
Primary injection up to 750A 4V output* 16V 40A output for secondary injection True RMS memory ammeter with single cycle capture Multi-function ti...
DE-16562 Hohen Neuendorf/OT Bergfelde
CU-Ps Primary Current Injection Test Set
CU-Ps Primary Current Injection Test Set
5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switc...
DE-16562 Hohen Neuendorf/OT Bergfelde
Typ TP M255S – Kalibrierbad-Temperaturkalibrator
Typ TP M255S – Kalibrierbad-Temperaturkalibrator
Temperaturbereich RT…255 °C Abmessung des Kalibrierbades: Ø60 x 163 mm Genauigkeit ±0,2 °C Highlights Einfachste Bedienung mit 4-Tasten Steuerun...
DE-16562 Hohen Neuendorf/OT Bergfelde
KV50-20D MK3 Test System
KV50-20D MK3 Test System
0-50kV output voltage 20mA maximum output current Auto-selecting 115/230V supply voltage Key operated supply switch to prevent unauthorised operati...
DE-16562 Hohen Neuendorf/OT Bergfelde
HT-Power 0701/0702 3P CL – Gerätetester (DGUV Vorschirft 3) zur Prüfung 1 und 3-phasiger Betriebsmittel bis 24kW / Schwe
HT-Power 0701/0702 3P CL – Gerätetester (DGUV Vorschirft 3) zur Prüfung 1 und 3-phasiger Betriebsmittel bis 24kW / Schwe
All in one – Gerätetester zur sicherheitstechnischen Überprüfung von Drehstrom- und Wechselstromverbrauchern nach DGUV Vorschrift 3 (BGV A3) inkl. akt...
DE-16562 Hohen Neuendorf/OT Bergfelde
200ADM-P Secondary Current Injection Test Set
200ADM-P Secondary Current Injection Test Set
The 200ADM-P is a current injection system with a wide range of advanced features including phase shift, data storage and harmonic analysis. 0-200A...
DE-16562 Hohen Neuendorf/OT Bergfelde
100ADM-F Filter Unit
100ADM-F Filter Unit
Forces test current to a sinusoid Improves timing accuracy when testing electro-mechanical relays 0.25A – 100A ranges High overload capability 50/...
DE-16562 Hohen Neuendorf/OT Bergfelde
KV30-40D MK3 Test System
KV30-40D MK3 Test System
The output voltage and current are metered by large, accurate true RMS digital meters 0-30kV output voltage 1.2kVA output capability Key operated s...
DE-16562 Hohen Neuendorf/OT Bergfelde
PCU1-SP MK3 Primärstrom-Einspritztestsystem
PCU1-SP MK3 Primärstrom-Einspritztestsystem
Der PCU1-SP Mk3 ist ein vielseitiges Primärstrom-Injektionstestsystem, ideal für Stabilitäts- und Leistungsschaltertests, mit direkter Ablesung von Wa...
DE-16562 Hohen Neuendorf/OT Bergfelde
100ADM MK5 Secondary Current Injection Test Set
100ADM MK5 Secondary Current Injection Test Set
0-100A output current True RMS metering with single cycle capture Auxiliary DC and AC output Multi-function auto-ranging timing system Current lim...
DE-16562 Hohen Neuendorf/OT Bergfelde
Typ TP17450 – Trockenblock-Temperaturkalibrator
Typ TP17450 – Trockenblock-Temperaturkalibrator
Temperaturbereich RT…450 °C Abmessung des Kalibriereinsatzes: Ø60 x 150 mm Genauigkeit ±0,6 °C Höchste Heizleistung Highlights Einfachste Bedie...
DE-16562 Hohen Neuendorf/OT Bergfelde
KAM Primary current injection testing
KAM Primary current injection testing
This substation testing device is designed to grant high current output when needed in substation commissioning activities. Main features High curre...
DE-16562 Hohen Neuendorf/OT Bergfelde
HT Instruments HT-Power 0701/0702 3P CL -- Gerätetester zur Prüfung 1 und 3-phasiger Betriebsmittel
HT Instruments HT-Power 0701/0702 3P CL -- Gerätetester zur Prüfung 1 und 3-phasiger Betriebsmittel
All in one - Gerätetester zur sicherheitstechnischen Überprüfung von Drehstrom- + Wechselstromverbrauchern nach DGUV Vorschrift 3 (BGV A3) inkl. Leist...
DE-16562 Hohen Neuendorf/OT Bergfelde
Z-OVR Cable Impedance Test System
Z-OVR Cable Impedance Test System
5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switc...
DE-16562 Hohen Neuendorf/OT Bergfelde

Die wer liefert was (wlw)-App ist da!

Nutzen Sie unsere verbesserte Anbietersuche oder erstellen Sie Ihre Anfragen jetzt auch mobil mit der neuen wlw-App für Einkäufer.

Jetzt im App Store herunterladen

App StoreGoogle Play